[See subsections ...]
Search Results "Bedpan Flushing Device"
Commonly Searched Documents
- 
    
  
  CHAPTER 5: DOORWAYS, CIRCULATION PATHS AND FARE COLLECTION DEVICES
  
 - BORA Classic Cooktop Extraction System
 - 
    
  
  407.2.1 Call Controls
  
Call buttons shall be raised or flush. EXCEPTION: Existing elevators shall be permitted to have recessed call buttons....
 - 
    
  
  407.2.1 Call Controls
  
Call buttons shall be raised or flush. EXCEPTION: Existing elevators shall be permitted to have recessed call buttons....
 - 
    
  
  1134A.6, Item 3
  
A clear maneuvering space at least 30 inches in width by 48 inches in length (762 mm by 1219 mm) shall be located outside the shower, flush and parallel to the control wall....
 - 
    
  
  1134A.6, Item 3
  
A clear maneuvering space at least 30 inches in width by 48 inches in length (762 mm by 1219 mm) shall be located outside the shower, flush and parallel to the control wall....
 - 
    
  
  LaCantina Contemporary Aluminum Bifold Door System Flush Sill
  Requires the Premium User plan or above. (Login or upgrade your account!)
 - 
    
  
  LaCantina Aluminum Thermally Controlled Slider System Flush Sill
  Requires the Premium User plan or above. (Login or upgrade your account!)
 - 
    
  
  407.2.1 Call Controls
  
Call buttons shall be raised or flush. EXCEPTION: Existing elevators shall be permitted to have recessed call buttons....
 - 
    
  
  11B-809.10.6.3 Floor space
  
A clear maneuvering space 30 inches (762 mm) wide minimum by 48 inches (1219 mm) minimum in length shall be located outside the shower, with the width flush with the control wall and the...
 - 
    
  
  11B-705.1.2.2 Curb ramps
  
Exception: On parallel curb ramps, detectable warnings shall be placed on the turning space at the flush transition between the street and sidewalk....
 - 
    
  
  11B-705.1.2.2 Curb ramps
  
Exception: On parallel curb ramps, detectable warnings shall be placed on the turning space at the flush transition between the street and sidewalk....
 - 
    
  
  11B-406.5.6 Grade breaks
  
Surface slopes that meet at grade breaks shall be flush....
 - 
    
  
  11B-406.5.6 Grade breaks
  
Surface slopes that meet at grade breaks shall be flush....
 - 
    
  
  11B-406.5.6 Grade breaks
  
Surface slopes that meet at grade breaks shall be flush....
 - 
    
  
  11B-608.9 Shower floor or ground surface
  
Where drains are provided, grate openings shall be ¼ inch (6.4 mm) maximum and flush with the floor surface....
 - 
    
  
  5.3.3.3 Location Where Walls Not Provided
  
The back of the seat shall be flush against the perimeter of the clear floor or ground space. ...
 - 
    
  
  Push Plates, Buttons, and Bars
  
Buttons that are raised or flush are easier to use than those that are recessed. (Elevator control buttons cannot be recessed, and input keys at ATM and fare machines must be raised.)...
 - 
    
  
  11B-608.9 Shower floor or ground surface
  
Where drains are provided, grate openings shall be ¼ inch (6.4 mm) maximum and flush with the floor surface....
 - 
    
  
  R304.5.2 Grade Breaks
  
Surface slopes that meet at grade breaks shall be flush....
 - 
    
  
  5 [§ 4.7.2]
  
These transition points are required to be flush and cannot have any abrupt level changes. Record any level change at the transitions....
 - 
    
  
  R305.2.3 Blended Transitions
  
Where raised pedestrian street crossings, depressed corners, or other level pedestrian street crossings are provided, detectable warning surfaces shall be placed at the flush transition...
 - 
    
  
  11B-608.9 Shower floor or ground surface
  
Where drains are provided, grate openings shall be ¼ inch (6.4 mm) maximum and flush with the floor surface....
 - TOTO Drake® Two-Piece Toilet, 1.6 GPF, ADA Compliant, Elongated Bowl Best Drake 2 Piece ADA Toilet