The clearance between the car platform sill and the edge of any hoistway landing shall be 1¼ inch (32 mm) maximum....
Search Results "Maximum Extent Practicable"
Commonly Searched Documents
-
11B-407.4.3 Platform to hoistway clearance
-
11B-809.9.5 Lower shelving
Lower shelving and/or drawer space shall be provided at a height of 48 inches (1219 mm) maximum above the finish floor....
-
11B-809.8.2 Door opening force
The opening force for primary entry exterior doors and secondary exterior doors shall be 8.5 pounds (38 N) maximum....
-
4.1.1(5)(a)
If full compliance with the requirements of these guidelines is structurally impracticable, a person or entity shall comply with the requirements to the extent it is not structurally impracticable...
-
11B-1007.2 Accessible routes
Where accessible routes intersect playing surfaces of holes, a 1 inch (25 mm) maximum curb shall be permitted for a width of 32 inches (813 mm) minimum....
-
Back Support: ADA Standard Section 903.4
Back support shall be 42 inches (1065 mm) long minimum and shall extend from a point 2 inches (51 mm) maximum above the seat surface to a point 18 inches (455 mm) minimum above the seat...
-
Seats: ADA Standard Section 604.4
Section 604.4 covers the current ADA Standards for the water closet seats.
-
Height: ADA Standard Section 606.3
Section 606.3 covers the current ADA Standards for the height of lavatories and sinks.
-
11B-604.5.1 Side wall
The side wall grab bar shall be 42 inches (1067 mm) long minimum, located 12 inches (305 mm) maximum from the rear wall and extending 54 inches (1372 mm) minimum from the rear wall with...
-
11B-407.2.2.3 Audible signals
Audible signals shall have a frequency of 1500 Hz maximum. Verbal annunciators shall have a frequency of 300 Hz minimum and 3000 Hz maximum....
- The RERC on Workplace Accommodations
-
F203.1 General
Sites, buildings, facilities, and elements are exempt from these requirements to the extent specified by F203....
-
Existing facilities
Existing facilities must remove barriers to the extent that doing so is readily achievable....
-
E202.1 General
ICT shall be exempt from compliance with the 508 Standards to the extent specified by E202....
-
§100.20 Aggrieved person
Aggrieved person includes any person who— (a) Claims to have been injured by a discriminatory housing practice; or (b) Believes that such person will be injured by a discriminatory...
-
11B-203.1 General
Sites, buildings, facilities, and elements are exempt from these requirements to the extent specified by 11B-203....
-
E202.1 General
ICT shall be exempt from compliance with the Revised 508 Standards to the extent specified by E202....
-
11B-203.1 General
Sites, buildings, facilities, and elements are exempt from these requirements to the extent specified by 11B-203....
-
11B-203.1 General
Sites, buildings, facilities, and elements are exempt from these requirements to the extent specified by 11B-203....
-
Line Spacing: ADA Standard Section 703.5.9
Spacing between the baselines of separate lines of characters within a message shall be 135 percent minimum and 170 percent maximum of the character height....
-
Height: ADA Standard Section 1009.4.2
The height of the transfer wall shall be 16 inches (405 mm) minimum and 19 inches (485 mm) maximum measured from the deck....
-
11B-1009.4.2 Height
The height of the transfer wall shall be 16 inches (406 mm) minimum and 19 inches (483 mm) maximum measured from the deck....
-
11B-703.5.9 Line spacing
Spacing between the baselines of separate lines of characters within a message shall be 135 percent minimum and 170 percent maximum of the character height....
-
Mirrors: ADA Standard Section 603.3
Section 603.3 covers the current ADA Standards for mirrors in toilet and bathing rooms.