This transfer surface is located on the longitudinal (long) side of the stretcher—either right or left side Rationale: Based upon full committee discussion and harmonization with Exam...
Search Results "Latch Side Clearance"
Commonly Searched Documents
-
M301.2.2, M302.2.2 Transfer Size
-
805.3 Clear Floor or Ground Space
A clear floor space complying with 305 shall be provided on each side of the bed. The clear floor space shall be positioned for parallel approach to the side of the bed....
-
805.3 Clear Floor or Ground Space
A clear floor space complying with 305 shall be provided on each side of the bed. The clear floor space shall be positioned for parallel approach to the side of the bed....
-
604.9.6 Dispensers
There shall be a clearance of 1 1/2 inches (38 mm) minimum below the grab bar. Dispensers shall not be of a type that controls delivery or that does not allow continuous paper flow....
-
604.9.6 Dispensers
There shall be a clearance of 1½ inches (38 mm) minimum below the grab bar. Dispensers shall not be of a type that controls delivery or that does not allow continuous paper flow....
-
11B-604.9.6 Dispensers
There shall be a clearance of 1½ inches (38 mm) minimum below the grab bar. Dispensers shall not be of a type that controls delivery or that does not allow continuous paper flow....
-
11B-604.9.6 Dispensers
There shall be a clearance of 1½ inches (38 mm) minimum below the grab bar. Dispensers shall not be of a type that controls delivery or that does not allow continuous paper flow....
-
604.5 Grab Bars
Grab bars shall be provided on the side wall closest to the water closet and on the rear wall. EXCEPTIONS: 1....
-
805.3 Clear Floor or Ground Space
A clear floor space complying with 305 shall be provided on each side of the bed. The clear floor space shall be positioned for parallel approach to the side of the bed....
-
7.4.11.3 Reach Ranges
If materials need to be obtained from or manipulated on a sign or kiosk, the sign or kiosk shall be designed to meet the reach ranges in section 308 of the ABAAS.
-
11B-604.3.2 Overlap
routes, clear floor space and clearances required at other fixtures, and the turning space....
-
11B-604.9.6 Dispensers
There shall be a clearance of 11/2 inches (38 mm) minimum below the grab bar. Dispensers shall not be of a type that controls delivery or that does not allow continuous paper flow....
-
604.5 Grab Bars
Grab bars shall be provided on the side wall closest to the water closet and on the rear wall. [ECTCR UFAS 4.34.5.2(3)] EXCEPTIONS: 1....
-
604.5 Grab Bars
Grab bars shall be provided on the side wall closest to the water closet and on the rear wall. EXCEPTIONS: 1....
-
§ 38.159(b)(13) Handrails
Platforms on lifts shall be equipped with handrails on two sides, which move in tandem with the lift, and which shall be graspable and provide support to standees throughout the entire lift...
-
1132A.1 Primary entry doors and required exit doors
The requirements of Sections 1126A.3 shall apply to maneuvering clearances at the side of the door exposed to common or public use spaces (e.g., entry or exit doors which open from the covered...
-
1132A.1 Primary entry doors and required exit doors
The requirements of Sections 1126A.3 shall apply to maneuvering clearances at the side of the door exposed to common or public use spaces (e.g., entry or exit doors which open from the covered...
-
T303 Handrails, Stanchions, and Handholds
The technical requirements for handrails, stanchions, and handholds include specifications on edges, cross sections, and clearances (i.e., space between gripping surface and adjacent surface...
-
Cross Section of Gripping Surfaces
considering whether the above cross section dimensions would be appropriate for the gripping surfaces of transfer supports on diagnostic equipment used by patients in a supine, prone, or side-lying...
-
11B-604.3.2 Overlap
routes, clear floor space and clearances required at other fixtures, and the turning space....
-
11B-604.3.2 Overlap
routes, clear floor space and clearances required at other fixtures, and the turning space....
-
Height
whether 6 inches minimum and 19 inches maximum above the transfer surface would be an appropriate height for transfer supports on diagnostic equipment used by patients in a supine, prone, or side-lying...
-
406.6 Diagonal Curb Ramps
Diagonal curb ramps with flared sides shall have a segment of curb 24 inches (610 mm) long minimum located on each side of the curb ramp and within the marked crossing....