Doors at exit passageways, exit discharge, and exit stairways shall be identified by tactile signs complying with 703.1, 703.2, and 703.5. Advisory 216.4.1 Exit Doors....
Search Results "In-Swinging Door"
Commonly Searched Documents
-
216.4.1 Exit Doors
-
H5
If there is a raised threshold, is it no higher than 3/4 inch at the door and beveled on both sides?...
- Yale 51 Series Industrial Door Closer
-
1132A.3, Item 6
6. The width of any component in the means of egress system shall not be less than the minimum width required by Section 1005.
-
1132A.3, Item 6
6. The width of any component in the means of egress system shall not be less than the minimum width required by Section 1005.
- SOSS Door Hardware UltraLatch Demonstration Video
-
Measuring Opening Force
Measuring Opening Force The maximum force pertains to the continuous application of force necessary to fully open a door, not the initial force needed to overcome the inertia of the door...
-
Toilet Rooms South (Briefing Theater)
The force required to push or pull open the men's toilet room door is 10 lbf, which exceeds the maximum allowable door opening force of 5 lbf. See Standards § 4.13.11(2)(b). kk....
-
1132A.4, Item 4
Secondary exterior doors onto decks, patios or balcony surfaces constructed of impervious materials (e.g., concrete, brick, flagstone) may have a maximum change in height from the interior...
-
§ 38.153(c)(1)
(1) Doors shall have a minimum clear width when open of 30 inches (760 mm), measured from the lowest step to a height of at least 48 inches (1220 mm), from which point they may taper to...
- Allegion LCN 6030 Series Overhead Concealed Door Control
-
Toilet Rooms North (Celebrity Spies)–Men [sic]
The force required to push or pull open the men's toilet room door is 10 lbf, which exceeds the maximum allowable door opening force of 5 lbf. See Standards § 4.13.11(2)(b). ee....
- Allegion LCN 3030 Series Overhead Concealed Door Control
-
Needs Photos or Technical Info
This article is a good start but, really could use some photos to illustrate the text. For example, what is a faucet that is placed out of reach for persons with cognitive...
- Sargent Wall and Frame Switch Interface for Door Operators
- Figure 404.2.4.2(a) Maneuvering Clearances at Doorways without Doors, Sliding Doors, Gates, and Folding Doors – Drawing from the U.S. Access Board
- BEA's MS21 Touchless Activation Sensor
-
T204.4 Doorways with Steps on Over-the-Road Buses
On over-the-road-buses, doorways with steps shall comply with T502.4.
-
Locks and Security Devices
Locks and Security Devices Permanently fixed portions of locks, including key locks, bolts, card readers, and push-button devices with number codes for general use by building...
-
4.8.4* Landings
Ramps shall have level landings at bottom and top of each ramp and each ramp run. Landings shall have the following features:
-
4.8.4 LANDINGS
Ramps shall have level landings at the bottom and top of each run. Landings shall have the following features: (1) The landing shall be at least as wide as the ramp run leading to...
-
§ 38.53(a) Clear width
(a) Clear width.
-
§ 38.73(a) Clear width
(a) Clear width—
-
§ 38.113 Doorways
[See subsections ...]