The proposed rule specified 1% scoping (on top of 6 required wheelchair spaces) for assembly areas with over 500 seats....
Search Results "Electric Vehicle Charging Space"
-
Minimum Number of Wheelchair Spaces
-
1005.4 Clear Floor or Ground Space
1005.4 Clear Floor or Ground Space....
-
Parallel Parking Spaces (R309.2) (Section-by-Section Analysis)
Parallel Parking Spaces (R309.2) (Section-by-Section Analysis) Where the adjacent sidewalk or available right-of-way is more than 4.3 meters (14 feet) wide, an access aisle must be provided...
-
4.3.2 Clear Floor or Ground Space
Tent pads and tent platforms shall have clear floor or ground space surrounding the tent that is at least 48 inches (1220 mm) wide. This space shall not overlap the ORAR....
-
T202 Accessible Means of Boarding and Alighting
All buses, OTRBs, and vans covered under the 2016 Non-Rail Vehicle Guidelines must provide at least one means of accessible boarding and alighting that serves all designated stops on the...
-
E202.5 ICT Functions Located in Maintenance or Monitoring Spaces
Where status indicators and operable parts for ICT functions are located in spaces that are frequented only by service personnel for maintenance, repair, or occasional monitoring of equipment...
-
407.2.1.3 Clear Floor or Ground Space
A clear floor or ground space complying with 305 shall be provided at call controls. Advisory 407.2.1.3 Clear Floor or Ground Space....
-
407.2.1.3 Clear Floor or Ground Space
A clear floor or ground space complying with 305 shall be provided at call controls. Advisory 407.2.1.3 Clear Floor or Ground Space....
-
T402 Ramps and Bridgeplates
The technical requirements for ramps and bridgeplates in the 2016 Non-Rail Vehicle Guidelines include provisions on design load, installation and operation, emergency operation, surfaces...
-
SELLING OR SERVING SPACE
§36.304(f) SELLING OR SERVING SPACE....
-
1002.5.1 Clear Floor or Ground Space
1002.5.1 Clear Floor or Ground Space....
-
11B-1002.4.4.2 Side entry
The amount of clear space needed within the ride, and the size and position of the opening are interrelated....
-
11B-1002.4.4.2 Side entry
The amount of clear space needed within the ride, and the size and position of the opening are interrelated....
-
4.27.3* Height
Electrical and communications system receptacles on walls shall be mounted no less than 15 in (380 mm) above the floor....
-
11B-1009.5.2 Transfer space
A transfer space of 60 inches (1524 mm) minimum by 60 inches (1524 mm) minimum with a slope not steeper than 1:48 shall be provided at the base of the transfer platform surface and shall...
-
11B-1009.5.2 Transfer space
A transfer space of 60 inches (1524 mm) minimum by 60 inches (1524 mm) minimum with a slope not steeper than 1:48 shall be provided at the base of the transfer platform surface and shall...
- Just Manufacturing Classroom Concealed Ledgemount Teardrop Handles Restricted Swing Faucet
-
1005.4 Clear Floor or Ground Space
At each location where there are railings, guards, or handrails complying with 1005.2.1, a clear floor or ground space complying with 305 shall be provided....
-
1005.4 Clear Floor or Ground Space
At each location where there are railings, guards, or handrails complying with 1005.2.1, a clear floor or ground space complying with 305 shall be provided....
- Access Board: Passing Spaces
-
R304.2.1 Turning Space
R304.2.1 Turning Space....
-
R304.3.1 Turning Space
R304.3.1 Turning Space....
-
Clearances: ADA Standard Section 1002.4.4
Clearances for wheelchair spaces shall comply with 1002.4.4. EXCEPTIONS: 1. Where provided, securement devices shall be permitted to overlap required clearances. 2....
-
§ 38.83(c)(3) Ramp threshold
The transition from roadway or station platform and the transition from vehicle floor to the ramp or bridge plate may be vertical without edge treatment up to 1/4 inch....