See ‘Agency Guide: Alternative text for links, controls and form elements’ (a link to the guide is provided in the back pages of this document) for....
Search Results "Back Wall"
Commonly Searched Documents
-
Links
-
D. Reach Range
[ADA Stds. 5.5] Yes __ No __ N/A __ Comments: ________________________________________ ...operational controls higher than 46" if they are set back 10"-24" from the edge of the counter...
-
406.8 Detectable Warnings
warning shall extend the full width of the curb ramp (exclusive of flared sides) and shall extend either the full depth of the curb ramp or 24 inches (610 mm) deep minimum measured from the back...
-
D2. Clear Passage
[See figure 24 in the appendix at the back of the checklist] Yes _____ No _____ If No, does another entrance have an accessible door or can both doors be propped open during voting...
-
How ALSs Operate
Couplers, such as ear phones, decode the signal from the receiver and convert it back into sound for the user....
-
Front Entry
throughout the house and records visitor while we are gone (security is the number one issue for older people) Deadbolts on inner and outer doors for security in the entry, garage, and back...
-
4.5.3* Carpet
If carpet or carpet tile is used on a ground or floor surface, then it shall be securely attached; have a firm cushion, pad, or backing, or no cushion or pad; and have a level loop, textured...
-
Accessible Classroom - Chevron Style
It is never appropriate to require that people using mobility devices sit only in the back or in one designated area. Click [here] ... for a full-page, printable handout....
-
11B-1009.2 Pool lifts
Pool lift seats with backs enable a larger population of persons with disabilities to use the lift....
-
1007.7.5 Openness
The sides other than the separation walls shall be at least 50 percent open, and the open area shall be distributed so as to minimize the accumulation of smoke or toxic gases....
-
505.10.1 Top and Bottom Extension at Ramps
Extensions shall return to a wall, guard, or the landing surface, or shall be continuous to the handrail of an adjacent ramp run....
-
1d
Does the 36" x 48" clear floor space directly outside the shower extend at least 12" past the seat wall of the shower to allow for a seat-to-seat transfer from the wheelchair?...
-
B. Braille Signs
Do the wall mounted signs provided for the rooms listed above have Braille and raised letters so that they can be read by persons who are blind or have low vision?...
-
1134A.6, Item 1.3
1.3 Other shower stall configurations shall measure at least 36 inches deep by 60 inches wide (914 mm by 1524 mm) with an entrance opening of at least 36 inches (914 mm) when a wall is...
-
505.10.1 Top and Bottom Extension at Ramps
Extensions shall return to a wall, guard, or the landing surface, or shall be continuous to the handrail of an adjacent ramp run....
-
1134A.6, Item 1.3
Other shower stall configurations shall measure at least 36 inches deep by 60 inches wide (914 mm by 1524 mm) with an entrance opening of at least 36 inches (914 mm) when a wall is installed...
-
11B-505.10.1 Top and bottom extension at ramps
Extensions shall return to a wall, guard, or the landing surface, or shall be continuous to the handrail of an adjacent ramp run....
-
11B-505.10.1 Top and bottom extension at ramps
Extensions shall return to a wall, guard, or the landing surface, or shall be continuous to the handrail of an adjacent ramp run. ...
-
7(2)(b)
(b) Bathrooms that have reinforced walls for grab bars (see Requirement 6) would meet section 100.205(c)(3)(iv) if: Note: Clear floor space beside tub may overlap with clear floor space...
-
1f
Is there a horizontal grab bar on the wall alongside the shower seat (but not behind the shower seat) for stabilization and to aid in transfer from a wheelchair to the folding shower seat...
-
1. Faucet Controls
Are the tub faucet controls positioned between the center of the end wall and the open side of the tub so persons with disabilities may approach and adjust the controls before they transfer...
-
M20
Is there a horizontal grab bar at least 36 inches long securely mounted behind the toilet 33 to 36 inches above the floor with one end no more than 6 inches from the side wall?...
-
1115B.4.1, Item 1
Therefore, existing water closets permitted and/or installed when those regulations were applicable with their centerlines located nominally more than 18 inches from the side wall should...
-
§ 36.402(b)(1)
remodeling, renovation, rehabilitation, reconstruction, historic restoration, changes or rearrangement in structural parts or elements, and changes or rearrangement in the plan configuration of walls...