Toe clearance shall extend 635 mm (2.1 ft) maximum under an element....
Search Results "Toe Clearance"
-
R405.2.2 Maximum Depth
-
R405.2.3 Minimum Required Depth
Where toe clearance is required at an element as part of a clear space, the toe clearance shall extend 430 mm (1.4 ft) minimum under the element....
-
R405.2.4 Width
Toe clearance shall be 760 mm (2.5 ft) wide minimum....
-
305.4 Knee and Toe Clearance
Unless otherwise specified, clear floor or ground space shall be permitted to include knee and toe clearance complying with 306....
-
306 Knee and Toe Clearance
-
306.2 Toe Clearance
Figure 306.2 Toe Clearance...
-
306.2.1 General
Space under an element between the finish floor or ground and 9 inches (230 mm) above the finish floor or ground shall be considered toe clearance and shall comply with 306.2....
-
306.2.2 Maximum Depth
Toe clearance shall extend 25 inches (635 mm) maximum under an element....
-
306.2.3 Minimum Required Depth
Where toe clearance is required at an element as part of a clear floor space, the toe clearance shall extend 17 inches (430 mm) minimum under the element....
-
306.2.4 Additional Clearance
Space extending greater than 6 inches (150 mm) beyond the available knee clearance at 9 inches (230 mm) above the finish floor or ground shall not be considered toe clearance....
-
306.2.5 Width
Toe clearance shall be 30 inches (760 mm) wide minimum....
-
Plumbing/Restrooms
accessories 11B-603 Clear floor space requirements at fixtures 11B-604 Compartment configuration side and end entry, toe...
-
Plumbing/Restrooms
accessories 11B-603 Clear floor space requirements at fixtures 11B-604 Compartment configuration side and end entry, toe...
-
7(2)(a)
allow a parallel approach by a person in a wheelchair; if parallel approach is not possible within the space, any cabinets provided would have to be removable to afford the necessary knee clearance...
-
7(2)(a)(i)
(i) Sufficient maneuvering space is provided within the bathroom for a person using a wheelchair or other mobility aid to enter and close the door, use the fixtures, reopen the door...
-
7(2)(b)
(b) Bathrooms that have reinforced walls for grab bars (see Requirement 6) would meet section 100.205(c)(3)(iv) if: Note: Clear floor space beside tub may overlap with clear floor...
-
7(2)(b)(i)
(i) Where the door swings into the bathroom, there is a clear space (approximately, 2' 6" by 4'0") within the room to position a wheelchair or other mobility aid clear of the path of...
-
7(2)(b)(v)
(v) Vanities and lavatories are installed with the centerline of the fixture a minimum of 1'3" horizontally from an adjoining wall or fixture. The top of the fixture rim is a maximum...
-
Clear Floor Space [4.2.4]
Clearances below plumbed fixtures are further defined specifically for toe space because of piping below the fixture....
-
4.17.4 Toe Clearances
In standard stalls, the front partition and at least one side partition shall provide a toe clearance of at least 9 in (230 mm) above the floor....
-
4.17.4 TOE CLEARANCES
In standard stalls, the front partition and at least one side partition shall provide a toe clearance of at least 9 in (230 mm) above the floor....
-
4.19.2 Height and Clearances
Provide a clearance of at least 29 in (735 mm) above the finish floor to the bottom of the apron. Knee and toe clearance shall comply with Fig. 31....
-
4.19.2 HEIGHT AND CLEARANCES
Provide a clearance of at least 29 in (735 mm) from the floor to the bottom of the apron. Knee and toe clearance shall comply with Fig. 31....