The SpectrAlert Advance Series of speakers and speaker strobes is designed to reduce ground faults. The plug-in design allows the installer to pre-wire mounting plates and dress the...
Search Results "Pull Station (Fire Alarm)"
Commonly Searched Documents
- Honeywell SP(W) / SPC Series Indoor Speaker/Strobes
- Honeywell SpectrAlert Advance Selectable Output Devices
- Honeywell SPWK/SPCWK Series Outdoor Speaker/Strobes
- TelCom Red Wall Mount Weatherproof Audible Horn Strobe - 180 cd ASWP-2475W-FR
-
Visible Alarms
The 1991 Standards, at section 4.1.1(3), require visible alarms to be provided where audible fire alarm systems are provided, but do not require areas used only by employees as work areas...
-
907.2.6.2.1 System initiation
Actuation of an automatic fire-extinguishing system, a manual fire alarm box or a fire detector shall initiate an approved fire alarm signal which automatically notifies staff....
-
907.2.8 Group R-1
A manual fire alarm system and an automatic fire detection system shall be installed in Group R-1 occupancies....
-
Wiring for Visible Alarms [§215.3]
Wiring for Visible Alarms [§215.3] All employee work areas served by audible fire alarms, regardless of size, must be designed to support later installation of visible alarms after...
-
A4.28 Alarms
[See subsections ...]
-
4.28 Alarms
[See subsections ...]
-
4.28 ALARMS
[See subsections ...]
-
A4.28 ALARMS
[See subsections ...]
-
11B-215.5 Residential facilities
Where provided in residential dwelling units required to comply with Section 11B-809.5, fire alarms shall comply with Chapter 9, Section 907.5.2.3.3 and carbon monoxide alarms shall comply...
-
Visible Alarms in Alterations to Existing Facilities
Visible Alarms in Alterations to Existing Facilities....
-
11B-702.1 General
Fire alarm systems shall have permanently installed audible and visible alarms complying with NFPA 72 and Chapter 9, Sections 907.5.2.1 and 907.5.2.3. [2010 ADAS] 702.1 General. ...
-
11B-702.1 General
Fire alarm systems shall have permanently installed audible and visible alarms complying with NFPA 72 and Chapter 9, Sections 907.5.2.1 and 907.5.2.3. [2010 ADAS] 702.1 General....
-
11B-702.1 General
Fire alarm systems shall have permanently installed audible and visible alarms complying with NFPA 72 and Chapter 9, Sections 907.5.2.1 and 907.5.2.3....
-
4.28.2* Audible Alarms
If provided, audible emergency alarms shall produce a sound that exceeds the prevailing equivalent sound level in the room or space by at least 15 dbA or exceeds any maximum sound level...
-
4.28.2* AUDIBLE ALARMS
If provided, audible emergency alarms shall produce a sound that exceeds the prevailing equivalent sound level in the room or space by at least 15 decibels or exceeds any maximum sound level...
-
702 Fire Alarm Systems
[See subsections ...]
-
702 Fire Alarm Systems
[See subsections ...]
-
1.1.3.2, Item 14.3
Fire alarm devices, equipment and systems in connection with any occupancy....
-
907.2.6.2 Group I-3
Group I-3 occupancies shall be equipped with a manual and automatic fire alarm system installed for alerting staff....
-
809.5.1 Building Fire Alarm System
809.5.1 Building Fire Alarm System....