[See subsections ...]
Search Results "Latch Side Clearance"
-
11B-306 Knee and toe clearance
-
11B-306 Knee and toe clearance
[See subsections ...]
- Figure 404.2.4.1(a) Maneuvering Clearances at Manual Swinging Doors and Gates: Front Approach, Pull Side – Drawing from the U.S. Access Board
- Figure 404.2.4.1(b) Maneuvering Clearances at Manual Swinging Doors and Gates: Front Approach, Push Side – Drawing from the U.S. Access Board
-
11B-505.5 Clearance
Clearance between handrail gripping surfaces and adjacent surfaces shall be 1½ inches (38 mm) minimum....
-
11B-505.5 Clearance
Clearance between handrail gripping surfaces and adjacent surfaces shall be 1½ inches (38 mm) minimum....
-
Unobstructed: ADA Standard Section 308.3.1
Section 308.3.1 covers the current ADA Standards for unobstructed side reach.
-
406.3 Sides of Curb Ramps
406.3 Sides of Curb Ramps. Where provided, curb ramp flares shall not be steeper than 1:10. Figure 406.3 Sides of Curb Ramps...
-
406.3 Sides of Curb Ramps
Figure 406.3 Sides of Curb Ramps...
-
Door Maneuvering Clearance
At doors that provide a latch side approach, the minimum depth of this clearance is increased where a closer is provided because additional space is needed to counteract the force of closers...
- Don-Jo Mfg., Inc. Door Flip Guards 1604
- TownSteel TDG129 Door Guard
- Don-Jo Mfg., Inc. Door Flip Guards 1603
-
11B-406.2.2 Sides of curb ramps
FIGURE 11B-406.2.2 ‡‡ SIDES OF CURB RAMPS...
-
11B-306.3 Knee clearance
[See subsections ...]
-
11B-306.2 Toe clearance
[See subsections ...]
-
11B-306.3 Knee clearance
[See subsections ...]
-
11B-306.2 Toe clearance
[See subsections ...]
-
11B-305.4 Knee and toe clearance
Unless otherwise specified, clear floor or ground space shall be permitted to include knee and toe clearance complying with Section 11B-306....
-
11B-305.4 Knee and toe clearance
Unless otherwise specified, clear floor or ground space shall be permitted to include knee and toe clearance complying with Section 11B-306....
-
11B-604.8.1.2 Doors
A door pull complying with Section 11B-404.2.7 shall be placed on both sides of the door near the latch....
-
11B-604.8.1.2 Doors
A door pull complying with Section 11B-404.2.7 shall be placed on both sides of the door near the latch....
-
11B-604.8.1.1.2 Maneuvering space with side-opening door
In a wheelchair accessible compartment with a door located in the side wall or partition, either in-swinging or out-swinging, a minimum 60 inches (1524 mm) wide and 60 inches (1524 mm) deep...
-
11B-604.8.1.1.2 Maneuvering space with side-opening door
In a wheelchair accessible compartment with a door located in the side wall or partition, either in-swinging or out-swinging, a minimum 60 inches (1524 mm) wide and 60 inches (1524 mm) deep...