Call buttons in elevator lobbies and halls shall be centered at 42 in (1065 mm) above the floor....
Search Results "Hall Call Console"
Commonly Searched Documents
-
4.10.3 HALL CALL BUTTONS
- ThyssenKrupp Elevator Signa 4 Signal Fixtures
-
Clear Floor or Ground Space: ADA Standard Section 407.2.1.3
Section 407.2.1.3 covers the current ADA Standards for the clear floor or ground space at elevator call controls.
-
11B-407.2.1 Call controls
Where elevator call buttons or keypads are provided, they shall comply with Sections 11B-407.2.1 and 11B-309.4 _|Operation|_. [2010 ADAS] 407.2.1 Call Controls. ...
-
11B-407.2.1 Call controls
Where elevator call buttons or keypads are provided, they shall comply with Sections 11B-407.2.1 and 11B-309.4 _|Operation|_. [2010 ADAS] 407.2.1 Call Controls....
-
11B-407.2.1 Call controls
Where elevator call buttons or keypads are provided, they shall comply with Sections 11B-407.2.1 and 11B-309.4. [2010 ADA Standards] 407.2.1 Call Controls....
-
11B-408.2.1 Call buttons
Elevator call buttons and keypads shall comply with Section 11B-407.2.1....
-
11B-411.2.1.2.5 Audio output
SECTION TITLE NOTES 11B-411.2.1.2.5 Audio output. Amends requirements so that operating...
-
11B-407.2.1.5 Signals
Call buttons shall have visible signals that will activate when each call is registered and will extinguish when each call is answered....
-
11B-407.2.1.4 Location
The call button that designates the up direction shall be located above the call button that designates the down direction. Exception: Reserved....
-
11B-206.6.1 Existing elevators
Where elements of existing elevators are altered, the same element shall also be altered in all elevators that are programmed to respond to the same hall call control as the altered elevator...
-
11B-411.2.1.2 Required features
Hall call consoles shall include a touch screen or keypad with display screen, an accessibility function button, and audio output loudspeaker....
-
11B-411.2.1.2 Required features
Hall call consoles shall include a touch screen or keypad with display screen, an accessibility function button, and audio output loudspeaker....
-
11B-411.2.1.2 Required features
Hall call consoles shall include a touch screen or keypad with display screen, an accessibility function button, and audio output loudspeaker....
-
11B-411.2.1.3.4 Position
SECTION TITLE NOTES 11B-411.2.1.3.4 Position Clarifies requirements for sloping of...
-
11B-407.2.1.2 Size and shape
Call buttons shall have square shoulders, be ¾ inch (19.1 mm) minimum in the smallest dimension and shall be raised 1/8 inch (3.2 mm) plus or minus 1/32 inch (0.8 mm) above the surrounding...
-
11B-407.2.1.2 Size and shape
Call buttons shall have square shoulders, be ¾ inch (19.1 mm) minimum in the smallest dimension and shall be raised 1/8 inch (3.2 mm) plus or minus 1/32 inch (0.8 mm) above the surrounding...
-
11B-407.2.1.2 Size and shape
Call buttons shall have square shoulders, be ¾ inch (19.1 mm) minimum in the smallest dimension and shall be raised 1/8 inch (3.2 mm) plus or minus 1/32 inch (0.8 mm) above the surrounding...
-
11B-407.2.1.3 Clear floor or ground space
A clear floor or ground space complying with Section 11B-305 shall be provided at call controls. Advisory 11B-407.2.1.3 Clear floor or ground space....
-
407.2.1 Call Controls
407.2.1 Call Controls. Where elevator call buttons or keypads are provided, they shall comply with 407.2.1 and 309.4. Call buttons shall be raised or flush....
- Mitsubishi Elevator Group Control System Replacement Panels
-
407.2.1 Call Controls
Where elevator call buttons or keypads are provided, they shall comply with 407.2.1 and 309.4. Call buttons shall be raised or flush....
-
407.2.1 Call Controls
Where elevator call buttons or keypads are provided, they shall comply with 407.2.1 and 309.4. Call buttons shall be raised or flush....
-
409.2 Call Buttons
409.2 Call Buttons. Call buttons shall be ¾ inch (19 mm) minimum in the smallest dimension and shall comply with 309....