A4.2 Space Allowances and Reach Ranges
-
A4.2 SPACE ALLOWANCES AND REACH RANGES
[See subsections ...]
-
11B-238.3 Practice putting greens, practice teeing grounds, and teeing stations at driving ranges
At least 5 percent, but no fewer than one, of practice putting greens, practice teeing grounds, and teeing stations at driving ranges shall be designed and constructed so that a golf car...
-
11B-238.3 Practice putting greens, practice teeing grounds, and teeing stations at driving ranges
At least 5 percent, but no fewer than one, of practice putting greens, practice teeing grounds, and teeing stations at driving ranges shall be designed and constructed so that a golf car...
-
Miniature Golf Facilities: ADA Standard Section 1007
[See subsections ...]
-
4.2.5 FORWARD REACH
If the clear floor space only allows forward approach to an object, the maximum high forward reach allowed shall be 48 in (1220 mm) (see Fig. 5(a))....
-
4.2.6* SIDE REACH
If the clear floor space allows parallel approach by a person in a wheelchair, the maximum high side reach allowed shall be 54 in (1370 mm) and the low side reach shall be no less than 9...
-
308.2.1 Unobstructed
Where a forward reach is unobstructed, the high forward reach shall be 48 inches (1220 mm) maximum and the low forward reach shall be 15 inches (380 mm) minimum above the finish floor or...
-
11B-308.2.1 Unobstructed
Where a forward reach is unobstructed, the high forward reach shall be 48 inches (1219 mm) maximum and the low forward reach shall be 15 inches (381 mm) minimum above the finish floor or...
-
308.2.1 Unobstructed
Where a forward reach is unobstructed, the high forward reach shall be 48 inches (1220 mm) maximum and the low forward reach shall be 15 inches (380 mm) minimum above the finish floor or...
-
4.2.5* Forward Reach
If the clear floor space only allows forward approach to an object, the maximum high forward reach allowed shall be 48 in (1220 mm) (see Fig. 5(a))....
-
4.2.6* Side Reach
If the clear floor space allows parallel approach by a person in a wheelchair, the maximum high side reach allowed shall be 54 in (1370 mm) and the low side reach shall be no less than 9...
-
308.2.1 Unobstructed
Where a forward reach is unobstructed, the high forward reach shall be 48 inches (1220 mm) maximum and the low forward reach shall be 15 inches (380 mm) minimum above the finish floor or...
-
308.2.1 Unobstructed
Where a forward reach is unobstructed, the high forward reach shall be 48 inches (1220 mm) maximum and the low forward reach shall be 15 inches (380 mm) minimum above the finish floor or...
-
11B-308.2.1 Unobstructed
Where a forward reach is unobstructed, the high forward reach shall be 48 inches (1219 mm) maximum and the low forward reach shall be 15 inches (381 mm) minimum above the finish floor or...
-
11B-308.2.1 Unobstructed
Where a forward reach is unobstructed, the high forward reach shall be 48 inches (1219 mm) maximum and the low forward reach shall be 15 inches (381 mm) minimum above the finish floor or...
-
A4.2.5 & A4.2.6 Reach
Reach ranges for persons seated in wheelchairs may be further clarified by Fig. A3(a)....
-
A4.2.5 & A4.2.6 REACH
Reach ranges for persons seated in wheelchairs may be further clarified by Fig. A3(a)....
-
4.3.7 Clear Floor Space for Reaching
For forward reaches, the longest reach range will also be at the level of the shoulder unless the individual has an upper extremity impairment that affects range of motion....
-
Reach Ranges and Operable Parts
REACH RANGES AND OPERABLE PARTS Forward and side reach 11B-308.2/3 Over projections 11B-308.2.2/3.2...
-
Reach Ranges and Operable Parts
REACH RANGES AND OPERABLE PARTS Forward and side reach 11B-308.2/3 Over projections 11B-308.2.2/3.2...
-
7. Should overhead play components such as track riders, ring ladders, monkey bars, and chin up bars be lowered to the recommended reach ranges?
Should overhead play components such as track riders, ring ladders, monkey bars, and chin up bars be lowered to the recommended reach ranges?...
-
22.1 Q. Must the switches on range hood kitchen ventilation fans be in accessible locations?
Kitchen ventilation fans located on a range hood are considered to be part of the appliance....
-