Dining Surfaces and Work Surfaces for Children's Use: ADA Standard Section 902.4
-
11B-902.4 Dining surfaces and work surfaces for children’s use
Accessible dining surfaces and work surfaces for children’s use shall comply with Section 11B-902.4. Exception: Dining surfaces and work surfaces that are used primarily by...
-
11B-902.4 Dining surfaces and work surfaces for children’s use
Accessible dining surfaces and work surfaces for children’s use shall comply with Section 11B-902.4. Exception: Dining surfaces and work surfaces that are used primarily by...
-
Height of Tables or Counters [4.32.4]
Height of Tables or Counters [4.32.4] Counter and table surface heights (28 to 34 inches) should be specified in consideration of the intended use....
-
36 CFR Part 1195 Standards for Accessible Medical Diagnostic Equipment - Preamble
The standards for medical diagnostic equipment (MDE Standards) contain minimum technical criteria to ensure that medical diagnostic equipment, including but not limited to, examination tables...
-
M301.4.1 Clearance in Base
The base of diagnostic equipment shall provide a clearance 39 inches (990 mm) wide minimum, 6 inches (150 mm) high minimum measured from the floor, and 36 inches (915 mm) deep...
-
M301.4.1 Clearance in Base
The base of the equipment shall provide a clearance 44 inches (1120 mm) wide minimum, 6 inches (150 mm) high minimum measured from the floor, and 36 inches (915 mm) deep minimum...
-
M301.4.1 Clearance in Base (Section-by-Section Analysis)
One commenter (medical association) noted that it would be difficult to meet the six-inch clearance from the floor when the table is lowered to 17 inches to allow for transfer....
-
5.2.1.1 Transfer Surface Width Recommendations for M301
As part of the deliberations, Committee members examined tables and chairs from various manufacturers during its meetings....
-
36 CFR Part 1195 Standards for Accessible Medical Diagnostic Equipment
The standards for medical diagnostic equipment (MDE Standards) contain minimum technical criteria to ensure that medical diagnostic equipment, including but not limited to, examination tables...
-
5.2.1 Transfer Surface Size Recommendations for M301
Depending on the configuration of the equipment, the transfer surface may occupy only a portion of an examination table or imaging bed platform....
-
a. Transfer Surface Adjustability
The MDE NPRM proposed that the same transfer surface height range of 17 inches minimum to 19 inches maximum be applied to both diagnostic equipment used in the supine, prone, or...
-
Fixed Seating and Tables
Fixed Seating and Tables If tables are provided, such as in restaurants and snack bars, and the tables are attached to the wall or floor (fixed), then 5% of the tables or at least one...
-
M301.4.2 Clearance Around Base
The base of diagnostic equipment shall provide a clearance 6 inches (150 mm) high minimum measured from the floor and 36 inches (915 mm) deep minimum measured from the edge of the...
-
M301.4.2 Clearance Around Base
The base of the equipment shall provide a clearance 6 inches (150 mm) high minimum measured from the floor and 36 inches (915 mm) deep minimum measured from the edge of the...
-
M301.4.2 Clearance Around Base
[See subsections ...]
-
Fixed or Built-in Seating and Tables [4.32]
[See subsections ...]
-
A4.32 SEATING, TABLES, AND WORK SURFACES
[See subsections ...]
-
4.32 SEATING, TABLES, AND WORK SURFACES
[See subsections ...]
- Brewer Assist Power Procedure Table
-
Accessible Medical Equipment
Importance of Accessible Examination Tables, Chairs and Weight Scales http://www.hfcdihp.org/products Exam Room Selection for Accessible Examination Tables & Chairs PDF , Word...
-
5.4.1 Transfer Support Location for M301 and M302
Figure 5.4.1 Location and Length of Transfer Supports (SOURCE: Midmark Corporation) A: Table seat depth, 17 inches minimum B: Transfer support length, 15 inches minimum C: Distance...
-
M305.2.2 Length
The length of transfer supports shall comply with M305.2.2.1 or M305.2.2.2.