The bold dashed line in the table and figure indicates the current ADA-ABA requirements, which vary based on the passage width and space available at the base of the turn....
Search Results "Clear Width"
Commonly Searched Documents
-
Accessible Pathway & Corridor: Minimum Clear Width Required for 180-degree Turn Around Barrier
-
§ 38.113(a) Clear width
(a) Clear width....
-
Clear Width and Vertical Clearance of Doors and Gates [§404.2.3]
Clear Width and Vertical Clearance of Doors and Gates [§404.2.3]...
-
A4.2.1 Wheelchair Passage Width
[See subsections ...]
-
A4.2.1 WHEELCHAIR PASSAGE WIDTH
[See subsections ...]
-
404.3.1 Clear Width
Doorways shall provide a clear opening of 32 inches (815 mm) minimum in power-on and power-off mode....
-
1018.3 Aisles in Groups B and M
In Group B and M occupancies, the minimum clear aisle width shall be determined by Section 1005.1 for the occupant load served, but shall be not less than that required for corridors by...
-
404.3.1 Clear Width
Doorways shall provide a clear opening of 32 inches (815 mm) minimum in power-on and power-off mode....
-
Handrails: ADA Standard Section 1009.3.3
The clear width between required handrails shall be 33 inches (840 mm) minimum and 38 inches (965 mm) maximum. EXCEPTIONS: 1....
-
1018.5 Aisles in other than assembly spaces and Groups B and M
In other than rooms or spaces used for assembly purposes and Group B and M occupancies, the minimum clear aisle capacity shall be determined by Section 1005.1 for the occupant load served...
-
Door Clear Width
Door Clear Width Open the door 90 degrees, measure from the face of the door to the edge of the door stop....
-
11B-404.3.1 Clear width
The minimum clear width for automatic door systems in a doorway shall provide a clear, unobstructed opening of 32 inches (813 mm) with one leaf positioned at an angle of 90 degrees from...
-
11B-404.3.1 Clear width
The minimum clear width for automatic door systems in a doorway shall provide a clear, unobstructed opening of 32 inches (813 mm) with one leaf positioned at an angle of 90 degrees from...
-
11B-404.3.1 Clear width
The minimum clear width for automatic door systems in a doorway shall provide a clear, unobstructed opening of 32 inches (813 mm) with one leaf positioned at an angle of 90 degrees from...
-
A4.2.1(2) Space Requirements for Use of Walking Aids
Although people who use walking aids can maneuver through clear width openings of 32 in (815 mm), they need 36 in (915 mm) wide passageways and walks for comfortable gaits....
-
A4.2.1(2) Space Requirements for Use of Walking Aids
Although people who use walking aids can maneuver through clear width openings of 32 in (815 mm), they need 36 in (915 mm) wide passageways and walks for comfortable gaits....
-
4.3.5.1 90-Degree Turn
Figure 4‒4 shows the accommodation model of the minimum clear width required for the 90-degree turn....
- Queue Solutions QueuePro Twin
-
Clearances [§403.5]
Clearances [§403.5] The minimum 36” continuous clear width of accessible routes can reduce to 32” at points, such as doorways, for a maximum distance of 24”....
-
1009.3.2 Stairway width
Stairways shall have a clear width of 48 inches (1219 mm) minimum between handrails....
-
Aisle: ADA Standard Section 904.3.1
Aisles shall comply with 403.
-
11B-904.3.1 Aisle
Aisles shall comply with Section 11B-403.
-
SECTION 1018 AISLES
[DSA-AC] In addition to the requirements of this section, means of egress, which provide access to, or egress from, buildings or facilities where accessibility is required for...
-
Doors and Gates: ADA Standard Section 410.6
Section 410.6 covers the current ADA Standards for the doors and gates of platform lifts.