by patients in a seated position (see M302.2.2), height of breast platforms on mammography equipment used by patients seated in a wheelchair (see M303.4.1), and standing supports in a vertical...
Search Results "Vertical Alignment"
Commonly Searched Documents
-
Other Sources
-
11B-703.7.2.6.3 Unisex toilet and bathing facilities
The vertices of the triangle symbol shall be located 1/4 inch (6.4 mm) maximum from the edge of the circle symbol with a vertex pointing upward....
-
11B-703.7.2.6 Toilet and bathing facilities geometric symbols
Where a door is provided the symbol shall be mounted within 1 inch (25 mm) of the vertical centerline of the door....
-
1009.7.2 Separation
The fire-resistance-rated construction shall extend vertically from the ground to a point 10 feet (3048 mm) above the floor level of the area for assisted rescue or to the roof line, whichever...
- Diaper Deck Infant Changing Table
- Defining and Delivering Disability-Competent Care - The Individualized Plan of Care
- HEWI Hinged Support Rail Duo
- Bobrick Swing-Up Grab Bar B-4998.99
- Sargent HP Bored Lock with Push/Pull Trim
-
Step 2: Identify the Presence of Limiting Factors
If the alignment can be relocated to get a more moderate slope, this limiting factor doesn't apply....
-
1.3 Previous Research
stopping on the sidewalk or ramp. 1.3.2 Detectable Warnings May Provide Visual Guidance Pedestrians who are visually challenged often have difficulty locating crosswalks, properly aligning...
-
11B-805.7 Built-in cabinets and work surfaces
Touch screen units shall be allowed to be vertically mounted with the centerline of the display screen no more than 52 inches above the floor in compliance with Section 11B-707.7.1.1....
- Kawneer North America 1010C Sliding Mall Front
- Grohe Grandera Two-Handle Bidet Mixer 1/2" M-Size Faucet
- Inpro Corporation JointMaster® 925 Fire Barrier System Expansion Joint Systems
-
2.2.3 Functional Reach
The five heights were normalized to the individual's vertical reach capabilities so that reaches were performed at, above and below shoulder height....
-
QUESTION: WHEN A RAIL OPERATOR CONSTRUCTS A NEW STATION PLATFORM OR ALTERS AN EXISTING STATION PLATFORM, DOES 49 CFR PART 37 REQUIRE THE RAIL OPERATOR ENSURE THAT THE PLATFORM IS AT LEAST 8 INCHES ABOVE TOP OF RAIL, EVEN IF THE RAILROAD OPERATOR WILL PROVIDE ACCESSIBILITY CONSISTENT WITH THE REQUIREMENTS OF SECTION 37.42?
., elderly persons) who might have difficulty ascending a vertical distance greater than the normal vertical gap between an 8-inch ATR platform and the first step of a railroad car....
-
233.1 General
Florida vertical accessibility requirements of s.553.509, F.S., as incorporated in section 201.1.1 require vertical access to all levels for accessible units....
-
608.6 Shower Spray Unit and Water
If an adjustable-height shower head on a vertical bar is used, the bar shall be installed so as not to obstruct the use of grab bars....
-
Shower Threshold
However, the Board has revised the specification to allow thresholds at transfer compartments to be vertical or rounded instead of beveled....
-
608.6 Shower Spray Unit and Water
If an adjustable-height shower head on a vertical bar is used, the bar shall be installed so as not to obstruct the use of grab bars....
-
4. COMMON PATH OF TRAVEL ITEMS
Running slope of ramps, not to exceed 1:12 (8.33%) • Cross slope of walks and ramps not to exceed 1:48 (2.083%) • Landings and level area slopes not to exceed 1:48 (2.083%) • Vertical...
-
5.4.9 Interruptions along Transfer Support Gripping Recommendation for M301 and M302
Section 505.6 specifies that the gripping surface on the vertical support structure that is necessary for supporting the grip must not be discontinuous....
-
11B-504.5 Nosings
Risers shall be permitted to slope under the tread at an angle of 30 degrees maximum from vertical....