M301.2.1 Height
The height of the transfer surface during patient transfer shall be 17 inches (430 mm) minimum and 19 inches (485 mm) maximum measured from the floor to the top of the transfer surface....
- Delta Adjustable Grab Bar 2-Setting Hand Shower 52002-DS
-
Medical Diagnostic Equipment Advisory Committee
Medical Diagnostic Equipment Advisory Committee MEDICAL DIAGNOSTIC EQUIPMENT ADVISORY COMMITTEE - Minority Report Regarding: 17 Inch Low Transfer Surface Height 09.27.13 These...
- Inpro ENDURANT® Shower Receptors
-
19 Inch Low Height
for architectural features that involve transfers (e.g., toilet seats, shower seats, dressing benches).”7 In addition, the Access Board recommended, “Where patient support surfaces are...
-
11B-1008.4.2 Clear floor or ground space
Where play components include a seat or entry point, designs that provide for an unobstructed transfer from a wheelchair or other mobility device are recommended....
-
7(2)(b)(vi)
(vi) Bathtubs and tub/showers located in the bathroom provide a clear access aisle adjacent to the lavatory that is at least 2'6" wide and extends for a length of 4'0" (measured from the...
-
5.2.1.3 Transfer Surface Size Recommendations for Stretchers (M301)
5.2.1.3 Transfer Surface Size Recommendations for Stretchers (M301) The Committee recommends a minimum transfer surface size of 28 inches wide by 17 inches deep for stretchers located...
-
5.4.1.2 Transfer and Positioning Support Location Recommendations for Imaging Equipment with Transfer Surfaces
transfer supports on tables with transfer depths of less than or equal to 24 inches and positioning supports for transfer depths greater than 24 inches....
-
M305.2 Transfer Supports (Section-by-Section Analysis)
(Significant Changes – Transfer Supports), the Access Board strengthened the transfer support requirements and added additional requirements in the final rule to ensure that supports are...
-
5.3.2 Transfer Sides for Equipment Used by Patients in a Supine, Prone, or Side-Lying Position
5.3.2 Transfer Sides for Equipment Used by Patients in a Supine, Prone, or Side-Lying Position....
- Delta Single Function Hand Shower With Grab Bar and Elbow RPW336HDF
- Delta Single Function Hand Shower with Grab Bar and Elbow RPW324HDF
-
1009.4.1 Clear Deck Space
A clear deck space of 60 inches (1525 mm) minimum by 60 inches (1525 mm) minimum with a slope not steeper than 1:48 shall be provided at the base of the transfer wall....
-
11B-1009.4.1 Clear deck space
A clear deck space of 60 inches (1524 mm) minimum by 60 inches (1524 mm) minimum with a slope not steeper than 1:48 shall be provided at the base of the transfer wall....
-
11B-1009.4.1 Clear deck space
A clear deck space of 60 inches (1524 mm) minimum by 60 inches (1524 mm) minimum with a slope not steeper than 1:48 shall be provided at the base of the transfer wall....
-
Users and Needs
Hospital patients, and especially nursing facility residents, due to their stature, reach, and strength characteristics, typically require the assistance of caregivers during transfer maneuvers...
-
Addendum G: Comparison of Transfer Abilities between Men and Women
The following figures G1 and G2 show the difference in transfer ability between men and women for high and low transfers....
- American Specialties Compact Rectangular Phenolic Fold-Up Shower Seat 8203
-
Secondary ticket market. (Section-by-Section Analysis)
The secondary ticket market, for the purposes of this rule, broadly means any transfer of tickets after the public accommodation's initial sale of tickets to individuals or entities....