Obstructions at side reaches are limited to a height of 34”....
Search Results "Side-Opening Door"
Commonly Searched Documents
-
Obstructed High Reach
-
M305.2.1.2 Side Transfer Supports
Transfer supports for transfer surfaces complying with M301.2.3.2 shall be capable of supporting transfer on each side of the transfer surface....
-
11B-404.2.8.2 Spring hinges
Door and gate spring hinges shall be adjusted so that from the open position of 70 degrees, the door or gate shall move to the closed position in 1.5 seconds minimum....
-
Bottom-Hinged Door Ovens: ADA Standard Section 804.6.5.2
Bottom-hinged door ovens shall have the work surface required by 804.3 positioned adjacent to one side of the door....
-
End-of-Row Stalls
If an out swinging door is provided at an end-of-row stall, maneuvering space of at least 18 inches at the latch side pull side must be provided....
-
F206.4.1 Public Entrances
All public entrances provided in accordance with Paragraph F206.4.1 (Public Entrances) of the ABAAS must have at least one entrance door complying with Section 404.3 (Automatic and Power-Assisted...
-
§ 38.93(a)(2)
then such doorway shall have, to the maximum extent practicable in accordance with the regulations issued under the Federal Railroad Safety Act of 1970 (49 CFR parts 229 and 231), a clear opening...
-
11B-406.5.1 Location
Curb ramps and the flared sides of curb ramps shall be located so that they do not project into vehicular traffic lanes, parking spaces, or parking access aisles....
-
Thresholds at Exterior Doors/Thresholds to Balconies or Decks
Additionally, the final Guidelines provide that at the primary entry doors to dwelling units with direct exterior access, outside landing surfaces constructed of impervious materials such...
- Besam SL500 A01 sliding door with outstanding performance
- Visitability
-
Question 10
Is the accessible entrance into the building free of obstacles that block the clear wall and floor space needed for opening the door (between 18 and 42 inches on the latch side of the door...
-
T503.3 Steps at Front Doorways
The walking surface on steps serving the front doorway of non-rail vehicles shall be lighted with 2 foot-candles (22 lux) minimum of illumination when the vehicle doors are open....
-
2. b. WIDE AND EASY TO OPEN EXTERIOR AND INTERIOR DOORS
[See subsections ...]
-
11B-604.8.1.1.1 Maneuvering space with in-swinging door
11B-604.8.1.1.1 Maneuvering space with in-swinging door....
-
(1) Transfer Surface Location for Diagnostic Equipment Used in the Supine, Prone, or Side-lying Position
These orientations are now identified as an end transfer surface and side transfer surface....
-
4.1.3(7)(c)
(c) Each door that is an element of an accessible route shall comply with 4.13....
-
4.1.3(7)(d)
(d) Each door required by 4.3.10, Egress, shall comply with 4.13....
-
11B-308.3.2 Obstructed high reach
Where a clear floor or ground space allows a parallel approach to an element and the high side reach is over an obstruction, the height of the obstruction shall be 34 inches (864 mm) maximum...
-
T502.3.1 Clear Width
Doorways shall provide a clear opening of 32 inches (810 mm) minimum....
-
10.3.1(9)
(9) In stations covered by this section, rail-to-platform height in new stations shall be coordinated with the floor height of new vehicles so that the vertical difference, measured...
-
4.1.3(7)(b)
(b) Within a building or facility, at least one door at each accessible space shall comply with 4.13....
-
A. Movie Basics, Captioning, and Audio Description Generally
There are, at present, two types of captions available for movies: open captions and closed captions. ...
-
Thresholds [§404.2.5]
A maximum height of 3/4” is permitted for existing or altered thresholds if they have a beveled edge on each side with a slope not steeper than 1:2....