E. Restaurants and Concessions:
PSE shall provide at least two (2) accessible tables on the accessible level in the Palace Grill Lounge in an area with the same service and décor as the rest of the restaurant. ...
-
Circulation Path
A person with disabilities is able to travel unassisted through that portion of the circulation path necessary to reach an area of refuge....
-
4.3.11.1(2)
Openings to the interior of the building located within 20 feet (6 m) of the area of rescue assistance shall be protected with fire assemblies having a three-fourths hour fire protection...
-
The ADA and City Governments: Common Problems
[See subsections ...]
-
382.51 What requirements must carriers meet concerning the accessibility of airport facilities?
At foreign airports, to which the ADAAG do not apply, Part 382 applies a performance requirement to make sure that passengers with a disability can readily use the facilities the carrier...
-
11B-221.2 Wheelchair spaces
Wheelchair spaces complying with Section 11B-221.2 shall be provided in assembly areas with fixed seating....
-
11B-408.2.2 Hall signals
Hall signals shall comply with Section 11B-407.2.2.
-
11B-408.3.2.2 Duration
Power-operated swinging doors shall remain open for 20 seconds minimum when activated.
-
11B-408.3.2.1 Power operation
Swinging doors shall be power-operated and shall comply with ANSI/BHMA A156.19.
-
11B-408.2.3 Hoistway signs
Signs at elevator hoistways shall comply with Section 11B-407.2.3.1.
-
11B-408.4.6 Car controls
Elevator car controls shall comply with Section 11B-407.4.6. Control panels shall be centered on a side wall.
-
11B-604.9.1 Location
The water closet shall be located with a wall or partition to the rear and to one side. The centerline of the water closet shall be 12 inches (305 mm) minimum and 18 inches (457 mm)...
-
1009.11 Instructions
In areas of refuge and exterior areas for assisted rescue, instructions on the use of the area under emergency conditions shall be posted....
-
1009.11 Instructions
In areas of refuge and exterior areas for assisted rescue, instructions on the use of the area under emergency conditions shall be posted....
-
11B-206.7.1 Performance areas and speakers’ platforms
Platform lifts shall be permitted to provide accessible routes to performance areas and speakers’ platforms. ...
-
11B-206.7.1 Performance areas and speakers’ platforms
Platform lifts shall be permitted to provide accessible routes to performance areas and speakers’ platforms. ...
-
11B-206.7.1 Performance areas and speakers’ platforms
Platform lifts shall be permitted to provide accessible routes to performance areas and speakers’ platforms....
-
ADA CHECKLIST FOR POLLING PLACES
Part 1 discusses polling place accessibility with a focus on the areas of a facility that may be used as a polling place on Election Day....
-
General
Areas of rescue assistance are spaces that have direct access to an exit, stair, or enclosure where individuals who are unable to use stairs can go to call for assistance and wait for evacuation...
-
1009.6.5 Two-way communication
Areas of refuge shall be provided with a two-way communication system complying with Sections 1009.8.1 and 1009.8.2....
-
11B-221.2.3.2 Vertical dispersion
Wheelchair spaces shall be dispersed vertically at varying distances from the screen, performance area, or playing field....