Search Results "1991 Standards"
Commonly Searched Documents
- Bradley Model 643 Standard Series Horizontal Recessed Soap Dispenser Model
- American Standard Monterrey Bottom-Mount Kitchen Faucet with Tubular Swivel Spout
-
II. Statutory and Regulatory Background
The Department selected the date of January 13, 1990 because it is fourteen months before March 13, 1991....
-
Conventions Used In This Guide
Black Text Used for text taken from CBC Black Text, Italicized Used by CBC to identify departures from IBC and/or 2010 ADA Standards...
-
ADAAG
ADAAG derives from an earlier federal standard, the Uniform Federal Accessibility Standards (UFAS)....
- Aluminum Dove Tail Series Pressure-Locked Grating
-
Section 36.406(f)(4)
Standards, 69 FR 58768, 58776 (Sept. 30, 2004)....
- Salsbury Industries 61000 Series Single Tier 3 Wide Standard Metal Lockers
- Salsbury Industries 62000 Series Double Tier 1 Wide Standard Metal Lockers
- Salsbury Industries 62000 Series Double Tier 3 Wide Standard Metal Lockers
- Salsbury Industries 63000 Series Triple Tier 3 Wide Standard Metal Lockers
-
Visible Alarms in Alterations to Existing Facilities
The 1991 Standards, at sections 4.1.3(14) and 4.1.6(1)(b), and sections 202.3 and 215.1 of the 2010 Standards require that when existing elements and spaces of a facility are altered, the...
-
Self Contained, Closed Products - Side Reach Range
Requires the Accessibility Specialist plan or above. (Login or upgrade your account!)
-
Development of the 2004 ADA/ABA Guidelines
These amendments to the 1991 ADAAG have not been adopted previously by the Department as ADA Standards....
-
Can parking signage height be considered a "safe harbor"?
The 1991 ADA Standards, Section 4.6.4 Signage requires accessible parking signage to be located so that it is not obscured by vehicles parked in the space. A4.6.4 Signage....
-
19. Are new play components added to an existing play area required to comply with the Standards even if there is not an accessible route from parking or the street to the play area?
Are new play components added to an existing play area required to comply with the Standards even if there is not an accessible route from parking or the street to the play area?...
-
Wheelchair Space Overlap in Assembly Areas
Section 4.33.3 of the 1991 Standards and the 2010 Standards, at sections 402, 403.5.1, 802.1.4, and 802.1.5, require walkways that are part of an accessible route to have a 36-inch minimum...
-
Fact Sheet: Highlights of the Final Rule to Amend the Department of Justice's Regulation Implementing Title III of the ADA
The ADA requires the Department to publish ADA design standards that are consistent with the minimum guidelines published by the U.S....
-
Maneuvering Clearance or Standby Power for Automatic Doors
Section 4.13.6 of the 1991 Standards does not require maneuvering clearance at automatic doors....
-
217 Telephones
1991 Standards for Accessible Design 2010 Standards for Accessible Design What’s New/Different 4.1.3(17)(b) All telephones...
-
209 Passenger Loading Zones
1991 Standards for Accessible Design 2010 Standards for Accessible Design What’s New/Different 4.1.2(5)(c) If passenger...
-
AVAILABLE DATA DO NOT SUPPORT DEPARTING FROM THE CURRENTLY ACCEPTED STANDARD OF 19-INCH TRANSFER SURFACE HEIGHT
Some tables may require installation of a modified top to meet the 19” standard but would not require changing out the installed base....
-
G.7.iii. - If an agency has a system in place for broadcasting streaming video, is it required to replace it with a system that meets the standards when the next lifecycle upgrade occurs?
Multimedia equipment is considered EIT and must meet the Access Board standards....
-
Standby Power for Platform Lifts
The 2010 Standards at section 207.2 require standby power to be provided for platform lifts that are permitted to serve as part of an accessible means of egress by the IBC....