9.a [§ 4.7.5] If the sidewalk at the top of the ramp (“x” in the illustration) is 48 inches wide or more, answer this question....
Search Results "Ramp Width"
Commonly Searched Documents
-
9.a [§ 4.7.5]
- Simplified Building Concepts: Building a D-Return - ADA Components
-
Question 4
Is the full width (minimum 3 feet) of the entire accessible route up to the business entrance clear of obstacles?...
-
Common Use Circulation Paths in Employee Work Areas
also contain exceptions to the technical requirements for accessible routes for circulation paths in employee work areas: • Machinery and equipment are permitted to reduce the clear width...
-
Question 11
Is the full width (minimum 3 feet) of the entire accessible route into and through the business clear of obstacles and trip hazards?...
-
410.6 Doors and Gates
End doors and gates shall provide a clear width 32 inches (815 mm) minimum. Side doors and gates shall provide a clear width 42 inches (1065 mm) minimum....
-
11B-410.6 Doors and gates
End doors and gates shall provide a clear width 32 inches (813 mm) minimum. Side doors and gates shall provide a clear width 42 inches (1067 mm) minimum....
-
A6
If a curb ramp is provided, is the running slope of the ramp surface (not counting the side flares) no more than 1:12 or 8.33% [ADA Standards § 4.7.2] Yes No...
-
3a.
If yes, is a ramp or sloped hallway provided? Yes _____ No _____ If yes, go to question E1-4. Note: A ramp, lift, or elevator can be used to provide access to floor levels....
-
§ 38.159(b)(8) Platform entrance ramp
(8) Platform entrance ramp....
-
R304.2.2 Running Slope
The running slope of the curb ramp shall cut through or shall be built up to the curb at right angles or shall meet the gutter grade break at right angles where the curb is curved....
-
4.8.4 LANDINGS
Ramps shall have level landings at the bottom and top of each run. Landings shall have the following features: (1) The landing shall be at least as wide as the ramp run leading to it...
- Figure 410.6 Platform Lift Doors and Gates – Drawing from the U.S. Access Board
-
H2
Does the door to the toilet room provide at least 32 inches clear passage width when the door is open 90 degrees? [ADA Standards § 4.13.5] Yes No...
-
M2
Does the door to the toilet room provide at least 32 inches clear passage width when the door is open 90 degrees? [ADA Standards § 4.13.5] Yes No...
-
T402.11 Gaps
When ramps or bridgeplates are deployed for boarding and alighting, gaps between the ramp or bridgeplate surface and floor of non-rail vehicles shall not permit passage of a sphere more...
- EZCurb Ramp - Vertical Barrier Removal Instructional Video
-
R207.1 General
A curb ramp, blended transition, or a combination of curb ramps and blended transitions complying with R304 shall connect the pedestrian access routes at each pedestrian street crossing....
- Inclusion Solutions Blue Parking Stop
-
Q11: Utility Trench Work and Curb Ramp Compliance
Q11: When will utility trench work require compliance with ADA curb ramp requirements?...
-
Width: ADA Standard Section 802.1.2
A single wheelchair space shall be 36 inches (915 mm) wide minimum Where two adjacent wheelchair spaces are provided, each wheelchair space shall be 33 inches (840 mm) wide minimum....
-
G. What are Detectable Warnings, Why are They Required, and Where Must They be Provided?
The ADA Standards require that curb ramps include features called “detectable warnings.”...
-
H16
[ADA Standards § 4.17.3] Yes No If No, note the width and depth of the stall. _________________...
-
Doors, Doorways, and Gates
In transient lodging facilities, doors and doorways in inaccessible guest rooms are required to provide a clear width of at least 32 inches....