The clear floor or ground space shall be positioned for a parallel approach to the space dedicated to a refrigerator/freezer with the centerline of the clear floor or ground space offset...
Search Results "Horizontal Position"
Commonly Searched Documents
-
11B-804.6.6 Refrigerator/freezer
-
1630.2(n)(1)
(1) In general, the term essential functions means the fundamental job duties of the employment position the individual with a disability holds or desires....
-
804.6.3 Dishwasher
Clear floor or ground space shall be positioned adjacent to the dishwasher door....
-
§1630.2(o)(1)(ii)
(ii) Modifications or adjustments to the work environment, or to the manner or circumstances under which the position held or desired is customarily performed, that enable an individual...
-
§1630.2(n)(1) In general
The term essential functions means the fundamental job duties of the employment position the individual with a disability holds or desires....
- Bobrick ConturaSeries Surface-Mounted Seat-Cover Dispenser B-4221
- Don-Jo Mfg., Inc. 5" Hospital Latch 4550
-
Appendix D: Photometric Measurements
This standard position was chosen to avoid the shadows and specular reflections (highlights) on the sides of the domes....
-
Reassignment
The Commission takes the position that if reassignment is required, an employer must place the employee in a vacant position for which he is qualified, without requiring the employee to...
-
Section 1630.2(m) Qualified Individual
This is sometimes referred to in the Rehabilitation Act caselaw as determining whether the individual is “otherwise qualified” for the position....
-
Grab bar clearance
Have local authorities accepted one-piece dispensers in toilet compartments that are recessed behind the horizontal grab bars? These units stick out ¼" or so....
-
11B-703.4.2 Location
that a clear floor space of 18 inches (457 mm) minimum by 18 inches (457 mm) minimum, centered on the tactile characters, is provided beyond the arc of any door swing between the closed position...
-
404.2.8.1 Door Closers and Gate Closers
Door closers and gate closers shall be adjusted so that from an open position of 90 degrees, the time required to move the door to a position of 12 degrees from the latch is 5 seconds minimum...
-
404.2.8.2 Spring Hinges
Door and gate spring hinges shall be adjusted so that from the open position of 70 degrees, the door or gate shall move to the closed position in 1.5 seconds minimum....
-
11B-404.2.8.1 Door closers and gate closers
Door closers and gate closers shall be adjusted so that from an open position of 90 degrees, the time required to move the door to a position of 12 degrees from the latch is 5 seconds minimum...
-
11B-404.2.8.1 Door closers and gate closers
Door closers and gate closers shall be adjusted so that from an open position of 90 degrees, the time required to move the door to a position of 12 degrees from the latch is 5 seconds minimum...
-
1131A.2 Changes greater than ½ inch
Changes in level greater than ½ inch (12.7 mm) shall be made by means of a sloped surface not greater than 1 unit vertical in 20 units horizontal (5-percent slope), or a ramp, elevator or...
-
1131A.1 Changes in level not exceeding ½ inch
When changes in level do occur, they shall be beveled with a slope no greater than 1 unit vertical in 2 units horizontal (50-percent slope)....
-
7(2)(b)(v)
(v) Vanities and lavatories are installed with the centerline of the fixture a minimum of 1'3" horizontally from an adjoining wall or fixture....
-
11B-1008.3.2.3 Transfer supports
Some examples of supports include a rope loop, a loop type handle, a slot in the edge of a flat horizontal or vertical member, poles or bars, or D rings on the corner posts....
-
Cross Slope
This may be expressed as the percentage of change in elevation or as a ratio of vertical distance to horizontal distance....
-
11B-1008.3.2.3 Transfer supports
Some examples of supports include a rope loop, a loop type handle, a slot in the edge of a flat horizontal or vertical member, poles or bars, or D rings on the corner posts....
-
§ 38.93(d)(3) Exception
Where platform set-backs do not allow the horizontal gap or vertical alignment specified in paragraph (d)(1) or (d)(2) of this section, car, platform or portable lifts complying with §38.95...
-
§ 38.95(b)(7) Platform gaps
When the lift is at car floor height with the inner barrier down (if applicable) or retracted, gaps between the forward lift platform edge and car floor shall not exceed 1/2 inch horizontally...