facilities covered by these requirements include, but are not limited to, reviewing stands, temporary classrooms, bleacher areas, stages, platforms and daises, fixed furniture systems, wall...
Search Results "Wing Wall"
Commonly Searched Documents
-
201.3 Temporary and Permanent Structures
-
604.8.1.6 Lavatory
new construction, the wheelchair accessible toilet compartment shall contain an accessible lavatory within it, which must be at least 19 inches wide by 17 inches deep, nominal size, and wall-mounted...
-
1134A.6, Item 1.2
water closet may project a maximum of 12 inches (305 mm) into the opening provided that a minimum of 36 inches (914 mm) clear space is maintained between the water closet and the shower wall...
-
Alteration
renovation, rehabilitation, reconstruction, historic restoration, changes or rearrangement of the structural parts or elements, and changes or rearrangement in the plan configuration of walls...
-
4.15.5(1)
(1) Wall- and post-mounted cantilevered units shall have a clear knee space between the bottom of the apron and the floor or ground at least 27 in (685 mm) high, 30 in (760 mm) wide, and...
-
Extensions
Extensions must be rounded or returned to the walls, floors, or posts....
-
Alteration of a recreation site, building, or facility
restoration, change in surface of circulation paths or vehicular ways, changes or rearrangement of the structural parts or elements, and changes or rearrangement in the plan configuration of walls...
-
4.15.5(1)
(1) Wall- and post-mounted cantilevered units shall have a clear knee space between the bottom of the apron and the floor or ground at least 27 in (685 mm) high, 30 in (760 mm) wide, and...
-
Time Management
to make an alarm after assigning ample time to complete a task Provide a checklist of assignments Supply an electronic or handheld organizer and train how to use effectively Use a wall...
-
4.34.6.10* KITCHEN STORAGE
(2) Door pulls or handles for wall cabinets shall be mounted as close to the bottom of cabinet doors as possible....
-
Can handrails or other elements overlap door maneuvering clearances?
However, door maneuvering clearances can be offset up to 8” from the face of the door or gate to accommodate wall thickness, casework, shelves, or other elements adjacent to doorways, including...
-
Can handrails overlap door maneuvering clearances?
However, door maneuvering clearances can be offset up to 8” from the face of the door or gate to accommodate wall thickness, casework, shelves, or other elements adjacent to doorways, including...
-
11B-804.2 Clearance
Clearances are measured from the furthest projecting face of all opposing base cabinets, counter tops, appliances, or walls, excluding hardware....
-
11B-201.3 Temporary and permanent structures
facilities covered by these requirements include, but are not limited to, reviewing stands, temporary classrooms, bleacher areas, stages, platforms and daises, fixed furniture systems, wall...
-
11B-903.6 Structural strength
Benches shall be affixed to the wall or floor....
-
11B-610.2 Bathtub seats
Permanent seats at the head end of the bathtub shall be 15 inches (381 mm) deep minimum and shall extend from the back wall to or beyond the outer edge of the bathtub....
-
11B-804.2 Clearance
Clearances are measured from the furthest projecting face of all opposing base cabinets, counter tops, appliances, or walls, excluding hardware. ◼...
-
11B-805.6 Hand washing fixtures, lavatories and sinks
inches (203 mm) minimum increasing to 29 inches (737 mm) high minimum above the finish floor or ground at the front edge of a counter with a built-in lavatory or at the front edge of a wall-mounted...
-
Attachment E
The sign shall be mounted on the wall adjacent to the latch side of the door with the centerline of the sign at 60 inches above the finished floor and situated such that a person can approach...
-
3. Lavatory knee clearance
the floor, a 27-inch-high clearance for knee space extending at least 8 inches from the front of the lavatory, and a 9-inch-high toe space extending not more than 6 inches from the back wall...
-
609.3 Spacing
The space between the wall and the grab bar shall be 1½ inches (38 mm). The space between the grab bar and projecting objects below and at the ends shall be 1½ inches (38 mm) minimum....
-
609.3 Spacing
The space between the wall and the grab bar shall be 1 1/2 inches (38 mm)....
-
804.3.1 Clear Floor or Ground Space
conditions are met: (a) the cabinetry can be removed without removal or replacement of the kitchen work surface; (b) the finish floor extends under the cabinetry; and (c) the walls...