Plumbing/Restrooms
-
11B-608.2.1 Transfer type shower compartments
Transfer type shower compartments shall be 36 inches (914 mm) by 36 inches (914 mm) clear inside dimensions measured at the center points of opposing sides and shall have a 36 inch (914...
-
804.2.1 Pass Through Kitchen
In pass through kitchens where counters, appliances or cabinets are on two opposing sides, or where counters, appliances or cabinets are opposite a parallel wall, clearance between all opposing...
-
608.3.3 Alternate Roll-In Type Shower Compartments
In alternate roll-in type shower compartments, grab bars shall be provided on the back wall and the side wall farthest from the compartment entry....
-
Caution regarding minimum Aisle Widths for aisles that serve "elements on both sides"
The interpretation of the meaning of aisles "serving elements on both sides" might be taken by some AHJs to mean public access to aisles that have self-serve items on both sides of an aisle...
-
11B-804.2.1 Pass through kitchen
In pass through kitchens where counters, appliances or cabinets are on two opposing sides, or where counters, appliances or cabinets are opposite a parallel wall, clearance between all opposing...
-
4.13.6 MANEUVERING CLEARANCES AT DOORS
Entry doors to acute care hospital bedrooms for in-patients shall be exempted from the requirement for space at the latch side of the door (see dimension "x" in Fig. 25) if the door is at...
-
804.2.1 Pass Through Kitchen
In pass through kitchens where counters, appliances or cabinets are on two opposing sides, or where counters, appliances or cabinets are opposite a parallel wall, clearance between all opposing...
-
608.2.1 Transfer Type Shower Compartments
Transfer type shower compartments shall be 36 inches (915 mm) by 36 inches (915 mm) clear inside dimensions measured at the center points of opposing sides and shall have a 36 inch (915...
-
221.2.3.2 Vertical Dispersion
In bleachers, wheelchair spaces shall not be required to be provided in rows other than rows at points of entry to bleacher seating. Advisory 221.2.3.2 Vertical Dispersion....
-
Entrance
An entrance includes the approach walk, the vertical access leading to the entrance platform, the entrance platform itself, vestibule if provided, the entry door or gate, and the hardware...
-
11B-233.3.1.2.5 Multi-story residential dwelling units in buildings with no elevator
residential dwelling units shall be calculated using the total number of multi-story residential dwelling units in buildings on a site and shall comply with the following: The primary entry...
-
ENTRANCE
An entrance includes the approach walk, the vertical access leading to the entrance platform, the entrance platform itself, vestibule if provided, the entry door or gate, and the hardware...
-
M304.2.2 Standing Supports (Section-by-Section Analysis)
The MDE NPRM proposed requiring standing supports on each side of the standing surface of diagnostic equipment used by patients in the standing position, and compliance with the technical...
-
F221.2.3.2 Vertical Dispersion
In bleachers, wheelchair spaces shall not be required to be provided in rows other than rows at points of entry to bleacher seating. Advisory F221.2.3.2 Vertical Dispersion....
-
Door Maneuvering Clearance
, hinge side)....
-
Kitchens and Kitchenettes
Section 804.2.1 requires that pass through kitchens, which have two entries and counters, appliances, or cabinets on two opposite sides or opposite a parallel wall, provide at least 40 inches...
-
608.2.1 Transfer Type Shower Compartments
Transfer type shower compartments shall be 36 inches (915 mm) by 36 inches (915 mm) clear inside dimensions measured at the center points of opposing sides and shall have a 36 inch (915...
- AJW Architectural Products U719 96"W x 48"H J-Mold Mirror - Four Sided Frame - Plate Glass
-
Mounting Location and Height [4.30.6]
The wheelchair maneuvering clearance required on the pull side of doors should allow adequate space....
-
11B-216.12 Amusement rides
Signs identifying the type of access provided on amusement rides shall be provided at entries to queues and waiting lines....
-
M303.2.6 Edge Protection (Section-by-Section Analysis)
requires platforms with wheelchair spaces that are raised more than 1½ inches in height to provide a minimum 2-inch-high edge protection, measured from the surface of the platform, on each side...