Yes, hall signs can be displayed horizontally instead of vertically. However, with call buttons, the button designating the up direction must be located above the one indicating the...
Search Results "Side Entry"
Commonly Searched Documents
-
Can hall and in-car signals be displayed horizontally (i.e., side-by-side) instead of vertically (i.e., one above the other)?
-
608.2.2 Standard Roll-In Type Shower Compartments
Standard roll-in type shower compartments shall be 30 inches (760 mm) wide minimum by 60 inches (1525 mm) deep minimum clear inside dimensions measured at center points of opposing sides...
-
11B-809.8.3 Door maneuvering clearance.
At the dwelling unit side of the primary entry doors, secondary exterior doors, and required exit doors maneuvering clearances shall be 44 inches (1118 mm) minimum in length measured...
-
1132A.4 Level floor or landing
The floor or landing on each side of a door shall be level....
-
1132A.5.1 General
The floor or landing on the dwelling unit side of the primary entry door and any required exit door shall have a minimum length of not less than 44 inches (1118 mm)....
-
11B-608.2.2 Standard roll-in type shower compartments
Standard roll-in type shower compartments shall be 30 inches (762 mm) wide minimum by 60 inches (1524 mm) deep minimum clear inside dimensions measured at center points of opposing sides...
-
Attachment I
The pressure required to operate the entry door is more than 20 pounds of force. Ensure that the force required to open the door is no more than 5 pounds of force. ...
-
608.2.1 Transfer Type Shower Compartments
Transfer type shower compartments shall be 36 inches (915 mm) by 36 inches (915 mm) clear inside dimensions measured at the center points of opposing sides and shall have a 36 inch (915...
-
Clear Floor or Ground Space: ADA Standard Section 1008.4.2
Where play components include a seat or entry point, designs that provide for an unobstructed transfer from a wheelchair or other mobility device are recommended....
-
11B-1008.4.2 Clear floor or ground space
Where play components include a seat or entry point, designs that provide for an unobstructed transfer from a wheelchair or other mobility device are recommended....
-
Are access key, card, or code entry systems permitted in elevators?
Yes, but fixed features of such systems must comply as operable parts. For example, card readers must be located within accessible reach ranges. Non-fixed portions, including keys...
-
608.5.3 Alternate Roll-In Type Shower Compartments
Where a seat is provided, the controls, faucets, and shower spray unit shall be located on the side wall adjacent to the seat 27 inches (685 mm) maximum from the side wall behind the seat...
-
608.5.3 Alternate Roll-In Type Shower Compartments
Where a seat is provided, the controls, faucets, and shower spray unit shall be located on the side wall adjacent to the seat 27 inches (685 mm) maximum from the side wall behind the seat...
-
608.3.3 Alternate Roll-In Type Shower Compartments
In alternate roll-in type shower compartments, grab bars shall be provided on the back wall and the side wall farthest from the compartment entry....
-
11B-608.3.3 Alternate roll-in type shower compartments
In alternate roll-in type shower compartments, grab bars shall be provided on the back wall and the side wall farthest from the compartment entry....
-
608.2.2 Standard Roll-In Type Shower Compartments
Standard roll-in type shower compartments shall be 30 inches (760 mm) wide minimum by 60 inches (1525 mm) deep minimum clear inside dimensions measured at center points of opposing sides...
-
804.2.1 Pass Through Kitchen
In pass through kitchens where counters, appliances or cabinets are on two opposing sides, or where counters, appliances or cabinets are opposite a parallel wall, clearance between all opposing...
-
11B-608.3.3 Alternate roll-in type shower compartments
In alternate roll-in type shower compartments, grab bars shall be provided on the back wall and the side wall farthest from the compartment entry....
-
Maneuvering Clearances [§404.2.4]
Clearance beyond the latch side is not required at entry doors to hospital patient rooms. ...
-
11B-804.2.1 Pass through kitchen
In pass through kitchens where counters, appliances or cabinets are on two opposing sides, or where counters, appliances or cabinets are opposite a parallel wall, clearance between all opposing...
-
11B-804.2.1 Pass through kitchen
In pass through kitchens where counters, appliances or cabinets are on two opposing sides, or where counters, appliances or cabinets are opposite a parallel wall, clearance between all opposing...
-
11B-233.3.1.2.4 Multi-story residential dwelling units in buildings with one or more elevators
In elevator buildings, facilities with multi-story residential dwelling units shall comply with the following: The primary entry of the multi-story residential dwelling unit shall...
-
4.13.6 Maneuvering Clearances at Doors
EXCEPTION: Entry doors to acute care hospital bedrooms for in-patients shall be exempted from the requirement for space at the latch side of the door (see dimension “x” in Fig. 25) if the...
-
Plumbing/Restrooms
Mirrors and accessories 11B-603 Clear floor space requirements at fixtures 11B-604 Compartment configuration side...