transportation facilities, in addition to the requirements of Sections 11B-217.4.1 through 11B-217.4.4, where at least one public pay telephone serves a particular entrance to a bus or rail...
Search Results "Non-Rail Vehicle"
-
11B-217.4.7 Transportation facilities
-
1005.2.1.1 Dispersion
Railings, guards, or handrails required to comply with 1005.2.1 shall be dispersed throughout the fishing pier or platform. Advisory 1005.2.1.1 Dispersion....
-
1005.2.1.1 Dispersion
Railings, guards, or handrails required to comply with 1005.2.1 shall be dispersed throughout the fishing pier or platform. Advisory 1005.2.1.1 Dispersion....
-
1005.2.1.1 Dispersion
Railings, guards, or handrails required to comply with 1005.2.1 shall be dispersed throughout the fishing pier or platform. Advisory 1005.2.1.1 Dispersion....
-
§ 38.159(b)(7) Platform gaps
When the platform is at vehicle floor height with the inner barrier (if applicable) down or retracted, gaps between the forward lift platform edge and the vehicle floor shall not exceed...
-
11B-1005.2.1.1 Dispersion
Railings, guards, or handrails required to comply with Section 11B-1005.2.1 shall be dispersed throughout the fishing pier or platform....
-
For a new public building, if EV charging equipment is not installed at this time, what is the extent of the infrastructure that an installer is required to show for plan check review?
RESPONSE: Plans and specifications must accurately describe the full extent of the work to be performed. Some enforcement jurisdictions (primarily city- and county building...
-
§8.21(b) Alterations to facilities
Alterations to existing non-housing facilities shall, to the maximum extent feasible, be made to be readily accessible to and usable by individuals with handicaps....
-
11B-220.2 Point-of-sale devices
Corrects code references for applicable technical requirements for point-of-sale devices, and adds requirement for point-of-sale devices at electric vehicle charging stations....
-
11B-707.9.1.1 Tactilely discernible numerical keypad
A tactilely discernible numerical keypad similar to a telephone keypad containing a raised dot with a dot base diameter between 1.5 mm and 1.6 mm and a height between 0.6 mm and 0.9...
-
11B-707.9.1.2 Other technology
Other technology, such as a radio frequency identification device, fingerprint biometrics, or some other mechanism that enables a visually impaired person to access the video touch...
-
Subpart C—Program Accessibility
[See subsections ...]
-
11B-707.9.1.1 Tactilely discernible numerical keypad
11B-707.9.1.1 Tactilely discernible numerical keypad. A tactilely discernible numerical keypad similar to a telephone keypad containing a raised dot with a dot base diameter between...
-
11B-707.9.1.2 Other technology
11B-707.9.1.2 Other technology. Other technology, such as a radio frequency identification device, fingerprint biometrics, or some other mechanism that enables a visually impaired...
-
11B-707.9.1.1 Tactilely discernible numerical keypad
A tactilely discernible numerical keypad similar to a telephone keypad containing a raised dot with a dot base diameter between 1.5 mm and 1.6 mm and a height between 0.6 mm and 0.9...
-
11B-707.9.1.2 Other technology
Other technology, such as a radio frequency identification device, fingerprint biometrics, or some other mechanism that enables a visually impaired person to access the video touch...
-
11B-233.3.1.2.6.1 Single building with one common (lobby) entrance
multifamily dwelling units, in a single building with one common (lobby) entrance, located on a site with difficult terrain conditions or unusual characteristics: All ground floor units in non-elevator...
-
6. What if I can’t afford to install a fixed lift in my pool, or it would be difficult to do so?
not readily achievable for a business to provide a fixed lift – that is, if it would be too difficult or expensive to make these changes – then a business may use other ways, such as a non-fixed...
-
203 General Exceptions
The 1991 Standards, at section 4.1.1, contain an exception that exempts “non-occupiable” spaces that have limited means of access, such as ladders or very narrow passageways, and that are...
-
§ 38.159(c)(3) Ramp threshold
The transition from roadway or sidewalk and the transition from vehicle floor to the ramp may be vertical without edge treatment up to 1/4 inch (6.5 mm)....
-
11B-503.5 Vertical clearance
Vehicle pull-up spaces, access aisles serving them, and a vehicular route from an entrance to the passenger loading zone and from the passenger loading zone to a vehicular exit shall provide...
-
11B-503.5 Vertical clearance
Vehicle pull-up spaces, access aisles serving them, and a vehicular route from an entrance to the passenger loading zone and from the passenger loading zone to a vehicular exit shall provide...
-
11B-233.3.1.2.6.1 Single building with one common (lobby) entrance
multifamily dwelling units, in a single building with one common (lobby) entrance, located on a site with difficult terrain conditions or unusual characteristics: All ground floor units in non-elevator...
-
§ 38.95(c)(6)(i) Requirement
When in use for boarding or alighting, the ramp or bridge plate shall be attached to the vehicle, or otherwise prevented from moving such that it is not subject to displacement when loading...