457 mm) of the latch side at an interior doorway, or within 24 inches (610 mm) of the latch side of an exterior doorway, projects more than 8 inches (203 mm) beyond the face of the door, measured...
Search Results "Measuring Technique"
-
11B-404.2.4.3 Recessed doors and gates
-
DETR
., 2000) was limited to measurement of device size and weight....
-
3.3.2 Unoccupied Device Length
unoccupied length for a powered wheelchair in our sample was 52 mm (2 in.) greater than the unoccupied length of the reference chair given in the standards, and the longest unoccupied length measured...
- 2101KG HR Digital Platform Scale with Mechanical Height Rod
-
Clear Width: ADA Standard Section 404.2.3
Section 404.2.3 covers the current ADA Standards for clear width at manual doors, doorways and manual gates that are part of an accessible route.
-
Carpet: ADA Standard Section 302.2
Section 302.2 covers the current ADA Standards for carpet.
-
[ADA Title III §36.104] Readily achievable
action; the number of persons employed at the site; the effect on expenses and resources; legitimate safety requirements that are necessary for safe operation, including crime prevention measures...
-
11B-505.10.3 Bottom extension at stairs
The horizontal extension of a handrail shall be 12 inches (305 mm) long minimum and a height equal to that of the sloping portion of the handrail as measured above the stair nosings....
-
11B-602.6 Water flow
The angle of the water stream shall be measured horizontally relative to the front face of the unit....
-
11B-404.2.3 Clear width
Clear openings of doorways with swinging doors shall be measured between the face of the door and the stop, with the door open 90 degrees....
-
11B-404.2.3 Clear width
Clear openings of doorways with swinging doors shall be measured between the face of the door and the stop, with the door open 90 degrees....
-
[ADA Title III §36.104] Readily achievable
action; the number of persons employed at the site; the effect on expenses and resources; legitimate safety requirements that are necessary for safe operation, including crime prevention measures...
-
11B-602.6 Water flow
The angle of the water stream shall be measured horizontally relative to the front face of the unit....
-
11B-505.10.3 Bottom extension at stairs
The horizontal extension of a handrail shall be 12 inches (305 mm) long minimum and a height equal to that of the sloping portion of the handrail as measured above the stair nosings....
- Access-Able Designs Wall Mounted Shower Transfer Bench SH-400
- Access-Able Designs Adult Dressing Bench D-101-42
- Access-Able Designs Rear Mount Tub Transfer Bench w/o Legs SH-414
-
§ 36.606(a)(2)
By the same token, certification would not be relevant to construction of a facility for children, if the regulations against which equivalency is measured do not address children´s facilities...
-
4 [§ 4.7.2]
To measure the gutter slope, place the level in the same position as the arrow in the illustration, with one end where the gutter meets the ramp and the other end towards the street....
-
703.2.5 Character Height
Character height measured vertically from the baseline of the character shall be 5/8 inch (16 mm) minimum and 2 inches (51 mm) maximum based on the height of the uppercase letter “I”....
-
R305.2 Placement
Where the back of curb edge is tooled to provide a radius, the border dimension should be measured from the end of the radius....
-
4.1.6(4)(d)
(ii) If existing thresholds measure 3/4 in (19 mm) high or less, and are beveled or modified to provide a beveled edge on each side, then they may be retained....
-
§ 37.135(d) Phase-in of implementation
If the date for full compliance specified in the plan is after January 26, 1993, the plan shall include milestones, providing for measured, proportional progress toward full compliance....