The horizontal distance from the transfer surface should be no more than 3 inches from the edge of the patient support surface....
Search Results "Horizontal Exit"
-
5.4.4.1 Transfer Support Distance from Transfer Surface for Stretchers
-
711.4.6 Floor fire doors
Floor fire doors used to protect openings in fire-resistance-rated floors shall be tested in the horizontal position in accordance with ASTM E 119, and shall achieve a fire-resistance rating...
-
R409.10.1 Top and Bottom Extension at Ramps
Ramp handrails shall extend horizontally above the landing for 305 mm (1.0 ft) minimum beyond the top and bottom of ramp runs....
-
Running Slope (Grade)
This may be expressed as a ratio of vertical distance to horizontal distance or as the percentage of change in elevation. ...
-
§ 38.53(d)(2) Exception
At key stations, the horizontal gap between at least one door of each such vehicle and the platform shall be no greater than 3 inches....
-
§ 38.73(d)(2) Exception
At key stations, the horizontal gap between at least one door of each such vehicle and the platform shall be no greater than 3 inches....
-
11B-407.4.10.3 Structural strength
Allowable stresses shall not be exceeded for materials used when a vertical or horizontal force of 250 pounds (1112 N) is applied at any point on the support rail, fastener, mounting device...
-
Path of Travel
35.151(b)(4)(ii) & 36.403(e)] (1) A "path of travel" includes a continuous, unobstructed way of pedestrian passage by means of which the altered area may be approached, entered, and exited...
- Pilot Rock CN-AMQ Amherst Collection Square Ash Receptacles
-
IS ASSISTANCE REQUIRED?
Once notified, people with a speech disability can read and follow standard exit and directional signs and use any standard means of egress from the building....
-
503.5 Vertical Clearance
Vehicle pull-up spaces, access aisles serving them, and a vehicular route from an entrance to the passenger loading zone, and from the passenger loading zone to a vehicular exit shall provide...
-
Water Flow: ADA Standard Section 602.6
Section 602.6 covers the current ADA Standards for the drinking fountain water flow.
-
11B-1002.4.3 Gaps
coordinated so that, when amusement rides are at rest in the load and unload position, the vertical difference between the floors shall be within plus or minus 5/8 inches (15.9 mm) and the horizontal...
-
11B-1002.4.3 Gaps
coordinated so that, when amusement rides are at rest in the load and unload position, the vertical difference between the floors shall be within plus or minus 5/8 inches (15.9 mm) and the horizontal...
-
11B-810.5.3 Platform and vehicle floor coordination
In light rail, commuter rail, and intercity rail systems where it is not operationally or structurally feasible to meet the horizontal gap or vertical difference requirements of part 1192...
-
11B-810.5.3 Platform and vehicle floor coordination
In light rail, commuter rail, and intercity rail systems where it is not operationally or structurally feasible to meet the horizontal gap or vertical difference requirements of part 1192...
-
§ 38.93(d)(2) Exception
At key stations, the horizontal gap between at least one accessible door of each such vehicle and the platform shall be no greater than 3 inches....
- Bobrick ClassicSeries Surface Mounted Seat-Cover Dispenser B-221
-
Sections 505.10.2 and 505.10.3
The requirement in the 1991 Standards that handrails extend horizontally at least 12 inches beyond the width of one tread at the bottom of a stair was changed in the 2004 ADAAG by the Access...
-
Weather Shelters
Weather Shelters Course weather shelters must be designed and constructed to allow a golf car to enter and exit, and have a clear floor or ground space of 60 inches by 96 inches minimum...
-
R409.10.3 Bottom Extension at Stairways
At the bottom of a stair flight, handrails shall extend at the slope of the stair flight for a horizontal distance at least equal to one tread depth beyond the last riser nosing....
-
H21
Is a horizontal grab bar at least 40 inches long securely mounted on the adjacent side wall 33 to 36 inches above the floor with one end no more than 12 inches from the back wall 33 to 36...
-
R409.10.2 Top Extension at Stairways
At the top of a stair flight, handrails shall extend horizontally above the landing for 305 mm (1.0 ft) minimum beginning directly above the first riser nosing....
-
4.8.5* Handrails
If a ramp run has a rise greater than 6 in (150 mm) or a horizontal projection greater than 72 in (1830 mm), then it shall have handrails on both sides....