structure or play equipment that is designated by ASTM F 1487 for unrestricted circulation around the play equipment and where it is predicted that a user would land when falling from or exiting...
Search Results "Horizontal Exit"
Commonly Searched Documents
-
USE ZONE
-
6. Grab Bars
Is there a horizontal grab bar at the head of the tub that is at least 12" long for stabilization and aid in transfer from a wheelchair to the fixed tub seat - see Figure 34 on page 25?...
-
11B-505.10.1 Top and bottom extension at ramps
Ramp handrails shall extend horizontally above the landing for 12 inches (305 mm) minimum beyond the top and bottom of ramp runs....
-
1131A.2 Changes greater than ½ inch
Changes in level greater than ½ inch (12.7 mm) shall be made by means of a sloped surface not greater than 1 unit vertical in 20 units horizontal (5-percent slope), or a ramp, elevator or...
-
1131A.2 Changes greater than ½ inch
Changes in level greater than ½ inch (12.7 mm) shall be made by means of a sloped surface not greater than 1 unit vertical in 20 units horizontal (5-percent slope), or a ramp, elevator or...
-
Sec.36.403(e)(1)
(1) A "path of travel'' includes a continuous, unobstructed way of pedestrian passage by means of which the altered area may be approached, entered, and exited, and which connects the altered...
-
§ 36.403(e)(1)
(1) A "path of travel" includes a continuous, unobstructed way of pedestrian passage by means of which the altered area may be approached, entered, and exited, and which connects the altered...
-
503.5 Vertical Clearance
Vehicle pull-up spaces, access aisles serving them, and a vehicular route from an entrance to the passenger loading zone, and from the passenger loading zone to a vehicular exit shall provide...
-
7(2)(b)(ii)
There also shall be clear space to allow persons using wheelchairs to reopen the door to exit....
-
503.5 Vertical Clearance
Vehicle pull-up spaces, access aisles serving them, and a vehicular route from an entrance to the passenger loading zone, and from the passenger loading zone to a vehicular exit shall provide...
- Pilot Rock CN-AMQ Amherst Collection Square Ash Receptacles
-
505.10.3 Bottom Extension at Stairs
At the bottom of a stair flight, handrails shall extend at the slope of the stair flight for a horizontal distance at least equal to one tread depth beyond the last riser nosing....
-
T404.3 Ramps and Bridgeplates
Where the space between the floor of non-rail vehicles and a boarding platform is greater than 2 inches (51 mm) horizontally or 5/8 inch (16 mm) vertically when measured at 50 percent passenger...
-
4. Grab Bars
Does the toilet in each accessible guestroom bathroom have a horizontal grab bar along the adjacent side wall that is at least 42" long and mounted 33"-36" above the floor for stabilization...
-
1131A.1 Changes in level not exceeding ½ inch
When changes in level do occur, they shall be beveled with a slope no greater than 1 unit vertical in 2 units horizontal (50-percent slope)....
-
1131A.1 Changes in level not exceeding ½ inch
When changes in level do occur, they shall be beveled with a slope no greater than 1 unit vertical in 2 units horizontal (50-percent slope)....
-
Lavatory & Accessory Layouts
The trash receptacle is preferred to be near the door to allow people to pull the door open with a paper towel and drop it into the receptacle before exiting....
-
USE ZONE
structure or play equipment that is designated by ASTM F 1487 for unrestricted circulation around the play equipment and where it is predicted that a user would land when falling from or exiting...
-
1132A.4 Level floor or landing
Primary entry doors, required exit doors or secondary exterior doors with changes in height between the interior surface or floor level and the exterior surface or floor level shall comply...
-
M303.2.6 Edge Protection
more than 1 ½ inches (38 mm) in height, edge protection 2 inches (51 mm) high minimum measured from the surface of the platform shall be provided on each side not providing entry to or exit...
- Bobrick ClassicSeries Surface Mounted Seat-Cover Dispenser B-221
-
Dispersion Requirements
Like the proposed rule, specifications are provided for horizontal (side to side) and vertical (front to back) dispersion....
-
704.9 Vertical separation of openings
exterior walls in adjacent stories shall be separated vertically to protect against fire spread on the exterior of the buildings where the openings are within 5 feet (1524 mm) of each other horizontally...
-
Character Height [4.30.3]
Recommendations: Both the horizontal and vertical viewing distance should be considered....