FAQ: How do I enter a New Upload in my Corada WorkSpace?
-
11B-407.2.2.1 Visible and audible signals
Where in-car signals are provided, they shall be visible from the floor area adjacent to the hall call buttons. Exceptions: Reserved. Reserved....
-
407.4.6.2.2 Arrangement
Buttons shall be arranged with numbers in ascending order. When two or more columns of buttons are provided they shall read from left to right....
-
105.2.2 ASME
ASME A17.1 requires a two-way means of emergency communications in passenger elevators....
-
105.2.2 ASME
ASME A17.1 requires a two-way means of emergency communications in passenger elevators....
-
Paragraph (e) (Advisory Guidance)
Provide larger buttons and controls, or buttons which are more widely spaced, to reduce the likelihood that a user will accidentally activate an adjacent control. b....
-
Jean Tessmer
I suggest you show how the button works and how the door opener is installed on the door....
-
11B-407.4.7.1.1 Type
Control buttons shall be identified by raised characters or symbols, white on a black background, complying with Section 11B-703.2, and Braille complying with Section 11B-703.3....
-
11B-407.4.7.1.1 Type
Control buttons shall be identified by raised characters or symbols, white on a black background, complying with Section 11B-703.2, and Braille complying with Section 11B-703.3....
-
11B-407.4.7.1.1 Type
Control buttons shall be identified by raised characters or symbols, white on a black background, complying with Section 11B-703.2 and Braille complying with Section 11B-703.3....
-
11B-407.4.7.2 Keypads
Keypads shall be identified by characters complying with Section 11B-703.5 and shall be centered on the corresponding keypad button. The number five key shall have a single raised dot....
-
11B-407.4.6.2.1 Size and shape
Buttons shall have square shoulders, be ¾ inch (19.1 mm) minimum in their smallest dimension and be raised 1/8 inch (3.2 mm) plus or minus 1/32 inch (0.8 mm) above the surrounding surface...
-
809.5.5.1 Notification
A button or switch shall be provided outside the residential dwelling unit primary entrance....
-
11B-809.5.5.1 Notification
A button or switch shall be provided outside the residential dwelling unit primary entrance....
-
809.5.5.1 Notification
A button or switch shall be provided outside the residential dwelling unit primary entrance....
-
11B-809.5.5.1 Notification
A button or switch shall be provided outside the residential dwelling unit primary entrance....
-
11B-809.5.5.1 Notification
A button or switch shall be provided outside the residential dwelling unit primary entrance....
- Harmar RPL Residential Vertical Platform Lift
-
FAQ: How do I enter a New CAD/BIM File in my Corada WorkSpace?
Adjust this setting by clicking the blue 'Edit' button to the right....
-
AREA OF REFUGE
An area where persons unable to use stairways can remain temporarily to await instructions or assistance during emergency evacuation....
-
809.5.5.1 Notification
A button or switch shall be provided outside the residential dwelling unit primary entrance....
-
11B-407.4.6.2.1 Size and shape
Buttons shall have square shoulders, be ¾ inch (19.1 mm) minimum in their smallest dimension and be raised 1/8 inch (3.2 mm) plus or minus 1/32 inch (0.8 mm) above the surrounding surface...
-
ASME
ASME A17.1 requires a two-way means of emergency communications in passenger elevators....
-
Visible and Audible Signals: ADA Standard Section 407.2.2.1
Section 407.2.2.1 covers the current ADA Standards for elevator visible and audible signals.