Where the diagnostic equipment is used in a reclined position, head and back support shall be provided. Where the incline of the back support can be modified while in use, head and...
Search Results "Companion Seat"
Commonly Searched Documents
-
M302.3.3 Head and Back Support
-
M303.2.2 Width
Wheelchair spaces shall be 36 inches (915 mm) wide minimum.
-
2. Equipment Clearances for Breast Platforms
The MDE NPRM proposed knee and toe clearance requirements for diagnostic equipment used by patients seated in wheelchairs that paralleled the knee and toe clearance requirements from the...
- Sloan WETS 2050.1001-1.28 Manual HET Flushometer and HET Wall Hung Water Closet
- TOTO® MS854114EL Commercial Eco UltraMax One-Piece Toilet ADA Height
-
Study Objectives
Level, highest and lowest heights for transfers to i) a seat with no handhelds present, ii) a seat with grab-bars and iii) a seat with grab-bars and a backrest. b....
-
Location and Size
appropriate for the location and size of transfer supports on diagnostic equipment used by patients in a supine, prone, or side-lying position, and diagnostic equipment used by patients in a seated...
-
M303.2.5 Surfaces (Section-by-Section Analysis)
The MDE NPRM proposed to require diagnostic equipment used by patients seated in a wheelchair to provide a wheelchair space with a surface that does not slope more than 1:48 in any direction...
- Whitehall Mfg. WH2142W2 Ligature-Resistant Toilet Wall Supply On-Floor Wall Waste
- Whitehall Mfg. Ligature Resistant Toilet Top Supply On-Floor
- Whitehall Mfg. WH2142T2 Ligature Resistant Toilet Top Supply On-Floor Wall Waste
-
Accessible Seating
Accessible Seating The minimum number of wheelchair spaces applies to individual spaces (33 inches wide minimum)....
-
M303 Diagnostic Equipment Used by Patients in a Wheelchair (Section-by-Section Analysis)
M303 in the final rule establishes the technical requirements for diagnostic equipment used by patients seated in a wheelchair, such as weight scales with wheelchair spaces and mammography...
-
Accessible Sports Facilities
), sports fields (such as softball, football, lacrosse, baseball, and soccer) and other sports (such as gymnastics and wrestling) Dressing, fitting, and locker rooms Team or player seating...
- Sloan WETS 2050.1401-1.28 G2 OPTIMA Plus Systems Activated HET Flushometer and HET Wall Hung Water Closet
- Sloan WETS 2050.1201-1.28 Solar-Powered HET Flushometer and HET Wall Hung Water Closet
- Delta Round Front Toilet C41901-WH
- American Standard Baby Devoro 1.28 gpf FloWise 10 Inch High Round Front Toilet
-
Knee & Toe Space [M303.2.4]
In order to image as much of the breast as possible, patients cannot be seated in the “natural” sitting position....
-
Real-Time Communication Etiquette for Communicating with Customers with Disabilities
Real-Time Communication Etiquette for Communicating with Customers with Disabilities Today, a lot of customer service takes place with voice calls over the telephone and Internet;...
-
5.8.3.1 Breast Platform Height Recommendations
Another member emphasized the importance of considering patients of short stature in addition to considering patients seated in a wheelchair....
-
M303.3 Entry
Where there is a change in level at the entry to wheelchair spaces, the change in level shall comply with M303.3.
-
M303.2.4.2.1 Depth
Wheelchair spaces shall include knee and toe clearance 17 inches (430 mm) deep minimum and 25 inches (635 mm) deep maximum.
-
M303.2.4.2.2 Height
Wheelchair spaces shall include toe clearance 9 inches (230 mm) high minimum above the floor measured to a depth of 6 inches (150 mm) maximum measured from the toe end of the...