If vertical clearance of an area adjoining an accessible route is reduced to less than 80 in (nominal dimension), a barrier to warn blind or visually-impaired persons shall be provided (...
Search Results "Bathtub Clearance"
-
4.4.2 Head Room
-
4.4.2 HEAD ROOM
If vertical clearance of an area adjoining an accessible route is reduced to less than 80 in (nominal dimension), a barrier to warn blind or visually-impaired persons shall be provided (...
-
Kitchens and Kitchenettes
Section 4.34.6 requires a clearance between opposing base cabinets, counters, appliances, or walls of at least 40 inches except in a U-shaped kitchen where the minimum clearance is 60 inches...
-
11B-806.2.3 Sleeping areas
At least one sleeping area shall provide a 36 inch (914 mm) by 48 inch (1219 mm) minimum clear space on both sides of a bed. The clear space shall be positioned for parallel approach...
-
Spacing: ADA Standard Section 609.3
Section 609.3 covers the current ADA Standards for the grab bar spacing between the wall, objects above, below and at the ends of the grab bar.
-
11B-806.2.3 Sleeping areas
At least one sleeping area shall provide a 36 inch (914 mm) by 48 inch (1219 mm) minimum clear space on both sides of a bed. The clear space shall be positioned for parallel approach...
-
Sleeping Areas: ADA Standard Section 806.2.3
At least one sleeping area shall provide a clear floor space complying with 305 on both sides of a bed. The clear floor space shall be positioned for parallel approach to the side of...
-
§ 38.95(a)(1) General
., lift, ramp or bridge plate) complying with either paragraph (b) or (c) of this section; sufficient clearances to permit a wheelchair or mobility aid user to reach a seating location;...
-
15(d)
(d) Within the timeframe set forth in subparagraph 15(a), HWI shall ensure that each Post-1993 Owned Hotel and Post-1993 Joint Venture Hotel has the required number of accessible...
- Symmons Duro® Tub Shower System 3S603-H321-V
- Delta Monitor® 13 Series Tub and Shower Trim - Push Button Diverter
-
14.4 Q. If a covered multifamily dwelling has a below grade common use parking garage, is there a requirement for a vertical clearance to allow vans to park?
In response to comments from the public that the Guidelines for parking specify minimum vertical clearance for garage parking, the Department responded: No national accessibility standards...
-
11B-213.2.1 Unisex (single-use or family) toilet and unisex bathing rooms
Unisex bathing rooms shall contain one shower or one shower and one bathtub, one lavatory, and one water closet....
-
Clearance Around Base (M301.4.2 and M302.4.2)
Clearance around the base of the equipment allows the legs of a portable floor lift to straddle the base....
-
11B-606.7 Sink depth
Where a forward approach is required at a sink, knee and toe clearance shall be provided in compliance with Section 11B-306....
-
11B-606.7 Sink depth
Where a forward approach is required at a sink, knee and toe clearance shall be provided in compliance with Section 11B-306....
-
M303.2.4.2 Other Equipment
Wheelchair spaces beneath diagnostic equipment other than breast platforms shall comply with M303.2.4.2.
-
2. Accessible lavatory with knee and toe space
2. Accessible lavatory with knee and toe space below, faucet controls usable with a loosely closed fist, clear floor space for front approach, and lowered mirror.
-
11B-606.7 Sink depth
Where a forward approach is required at a sink, knee and toe clearance shall be provided in compliance with Section 11B-306....
-
5.7.1.2 Lift Compatibility Clearance in Base for Imaging Equipment (M301)
5.7.1.2 Lift Compatibility Clearance in Base for Imaging Equipment (M301) The Committee recommends the use of alternative means of access by an overhead lift in place of clearances in...
-
Voting Area
Within the voting area there must be enough clearance for an individual with a disability to access and use all the voting equipment....
-
4.17.5* DOORS
If toilet stall approach is from the latch side of the stall door, clearance between the door side of the stall and any obstruction may be reduced to a minimum of 42 in (1065 mm)....
-
4.17.5* Doors
If toilet stall approach is from the latch side of the stall door, clearance between the door side of the stall and any obstruction may be reduced to a minimum of 42 in (1065 mm) (Fig. 30...