Where play components require transfer to entry points or seats, the entry points or seats shall be 11 inches (280 mm) minimum and 24 inches (610 mm) maximum from the clear floor or ground...
Search Results "Transfers of Privately Held Equity Interest"
-
1008.4.4 Entry Points and Seats
-
III−1.1000 General
The obligations of title III only extend to private entities. State and local government entities are public entities covered by title II of the ADA, not by title III....
-
5.3 Transfer Sides Recommendations
5.3 Transfer Sides Recommendations...
-
Transfer Supports (M301.3.1, M302.3.1, and M305.2)
M301.3.1 and M302.3.1 would require transfer supports to be provided for use with the transfer sides....
-
§ 37.37(b)
(b) Shuttle systems and other transportation services operated by privately-owned hotels, car rental agencies, historical or theme parks, and other public accommodations are subject to the...
-
1009.4.5 Grab Bars
At least one grab bar complying with 609 shall be provided on the transfer wall. Grab bars shall be perpendicular to the pool wall and shall extend the full depth of the transfer wall....
-
11B-1009.4.5 Grab bars
At least one grab bar complying with Section 11B-609 shall be provided on the transfer wall....
-
1009.4.5 Grab Bars
At least one grab bar complying with 609 shall be provided on the transfer wall. Grab bars shall be perpendicular to the pool wall and shall extend the full depth of the transfer wall....
-
Transfer Surface Height (M301.2.1 and M302.2.1)
M301.2.1 and M302.2.1 would require the height of the transfer surface during patient transfer to be 17 inches minimum and 19 inches maximum measured from the floor to the top of the transfer...
-
Clear Deck Space
Clear Deck Space Clear deck space of 60 by 60 inches minimum, with a slope of not more than 1:48, must be provided at the base of a transfer wall....
-
5.4.1 Transfer Support Location for M301 and M302
5.4.1 Transfer Support Location for M301 and M302 Description: Transfer supports assist individuals while making transfers on to the transfer area....
-
Chapter 3: Study findings
[See subsections ...]
-
1009.4.5 Grab Bars
At least one grab bar complying with 609 shall be provided on the transfer wall. Grab bars shall be perpendicular to the pool wall and shall extend the full depth of the transfer wall....
-
11B-1009.4.5 Grab bars
At least one grab bar complying with Section 11B-609 shall be provided on the transfer wall....
-
11B-1009.4.5 Grab bars
At least one grab bar complying with Section 11B-609 shall be provided on the transfer wall....
-
Spas
Spas Spas must provide at least one accessible means of entry, which can be a pool lift, transfer wall, or transfer system. ...
-
5.4.2 Transfer Support Length for M301 and M302
balance against while performing a transfer....
-
The Brewer Company, LLC
The proposed rule recommended that the height of the transfer surface during patient transfer shall be 17 inches minimum and 19 inches maximum measured from the floor to the top of the transfer...
-
c. Transfer Surface Size for Diagnostic Equipment Used by Patients in the Supine, Prone, or Side-lying Position
Those commenters supporting a smaller transfer surface raised concerns about the ability to transfer with a large surface preventing the patient from reaching transfer supports on the opposite...
- Autoadapt Turny Evo
- Willoughby Industries US-HC Cabinet Shower
-
5.4.1.1 Transfer Support Location for Stretchers
5.4.1.1 Transfer Support Location for Stretchers. The transfer surface for stretchers should be oriented along the long side of the surface....
-
Section 36.201(b) (Preamble, Section-by-Section Analysis)
Thus, the landlord would generally be held responsible for making readily achievable changes and providing auxiliary aids and services in common areas and for modifying policies, practices...
-
Addendum E: Comparison of participants tested at the National Disabled Veterans Winter Sports Clinic (NDVWSC) compared to the participants tested at the Human Engineering Research Laboratories and Hiram G. Andrews Center
At the time this addendum was composed, there were 31 participants enrolled in the phase 2 study at HERL (27 men and 4 women). This group of subjects was compared to all the...