Handles, pulls, latches, locks, and other operable parts on doors and gates shall comply with 309.4....
Search Results "Shower Door"
Commonly Searched Documents
-
404.2.7 Door and Gate Hardware
-
404.3.1 Clear Width
The minimum clear width for automatic door systems in a doorway shall be based on the clear opening provided by all leaves in the open position. [ECTCR UFAS 4.13.5]...
-
404.3.1 Clear Width
The minimum clear width for automatic door systems in a doorway shall be based on the clear opening provided by all leaves in the open position....
-
11B-224.8.2 More than 50-bed facilities
When separate shower facilities are provided for men and women, at least one roll-in shower shall be provided for each group....
- ADAEZ Pro Plus Automatic Door Opener Installing Operator Mounting Bracket and Door Arm Pivot Video
-
H6
If the entry has a vestibule, is there a 30-inch by 48-inch clear floor space inside the vestibule where a wheelchair or scooter user can be outside the door swing?...
- Access-Able Designs Shower Transfer Bench SH-400-2SDL
-
Thresholds at Doorways
The 1991 Standards, at section 4.13.8, require the height of thresholds at doorways not to exceed ½ inch and thresholds at exterior sliding doors not to exceed ¾ inch....
-
(4) [sic] Thresholds at exterior doors
Subject to the exceptions for thresholds and changes in level at exterior areas constructed of impervious materials, the final Guidelines continue to specify that thresholds at exterior doors...
-
H2
Does the door to the toilet room provide at least 32 inches clear passage width when the door is open 90 degrees? [ADA Standards § 4.13.5] Yes No...
-
M2
Does the door to the toilet room provide at least 32 inches clear passage width when the door is open 90 degrees? [ADA Standards § 4.13.5] Yes No...
-
B. Measuring Clear Passage at Doors
Verifying the clear passage width at standard hinged doors requires an understanding of exactly where to measure....
-
Standard Stall
The clearances required for stall doors are different than those specified for conventional passage doors and gates in 4.13.6 since partition doors are generally lighter and easier to open...
-
Restrooms Main Lobby
The restroom vestibule door does not have the required minimum of 18" maneuvering clearance on the latch side of the door. See Standards § 4.13.6. l....
- Inpro Corporation Clickeze® ADA Shower Curtain
-
Controls
Clear floor space at controls should be located outside the door swing....
-
Section D: Entrances
opening (one door or one active leaf of a double door) at least 32"?...
-
11B-411.4.1 Car dimensions
Inside dimensions of elevator cars and clear width of elevator doors shall comply with Section 11B-407.4.1....
-
11B-216.4.1 Exit doors
Signs required by Chapter 10, Section 1013.4 at doors to exit passageways, exit discharge, and exit stairways shall comply with Sections 11B-703.1, 11B-703.2, 11B-703.3, and 11B-703.5....
-
Re: 404.2.6 Doors in Series and Gates in Series
My understanding is that it was written to keep wheelchair users from having to fight two doors at once. ...
- Besam SL500 A02 for sustainable automatic doors
- Symmons Duro® Tub Shower System 3S603-H321-V
-
D. Clear Floor Space
If there is a vestibule without fully automatic doors, is there a 30"x48" clear floor space where one can be outside the swing of a hinged door (i.e.: for out-swinging doors, at least 7'...
-
C. Clear Floor Space
When there is a vestibule into the public or employee restroom that does not have fully automatic doors, is there a 30"x48" clear floor space where one can be outside the swing of a hinged...