(3) A portion of a one-hour fire-resistive corridor (complying with local requirements for fire-resistive construction and for openings) located immediately adjacent to an exit enclosure...
Search Results "Portable Fire Extinguisher Cabinet"
-
4.3.11.1(3)
-
Communication
He kept going behind the cabinets, opening up drawers, this is a fossil from such and such and putting things in my hands and explaining it. It was the best experience I ever had.”...
-
5. Accessible Features
(For example, repairing cracks in sidewalks on exterior routes; placing portable display racks and potted plants so they do not impede exterior and interior routes; snow removal on exterior...
-
Raised Letter Braille requirement - Exterior
Building Address is on one corner of the building; a fire department requirement 3. ...
-
2.1
The parties further agree that this Consent Order shall extinguish all claims for relief and all counterclaims between the United States and Cinemark in the aforementioned litigation. ...
-
Horizontal Exits [IBC §1021 (2003), §1005.3.5 (2000)]
A horizontal exit compartmentalizes a building allowing occupants to exit the area containing the origin of a fire into another portion of the building that is protected by fire-resistance-rated...
-
711.3.1 Through penetrations
Through penetrations of fire-resistance-rated walls shall comply with Section 711.3.1.1 or 711.3.1.2....
-
§382.133(e)(1)
(1) Any applicable requirement for a manufacturer-affixed label to reflect that the device has been tested to meet applicable FAA requirements for medical portable electronic devices;...
-
§382.133(c)(1)
(1) A portable oxygen concentrator (POC), a ventilator, a respirator or a continuous positive airway pressure machine that displays a manufacturer's label that indicates the device meets...
-
1.1.4 Appendices
with Health and Safety Code Section 18901 et. seq. for Building Standards Law, Health and Safety Code Section 17950 for State Housing Law and Health and Safety Code Section 13869.7 for Fire...
-
704.8.2 First story
In occupancies other than Group H, unlimited unprotected openings are permitted in the first story of exterior walls facing a street that have a fire separation distance of greater than...
-
711.4.2 Membrane penetrations
Penetrations of membranes that are part of a fire-resistance-rated horizontal assembly shall comply with Section 711.4.1.1 or 711.4.1.2....
-
711.4.1 Through penetrations
Through penetrations of fire-resistance-rated horizontal assemblies shall comply with Section 711.4.1.1 or 711.4.1.2....
-
Exit Doors: ADA Standard Section 216.4.1
Section 216.4.1 covers scoping requirements in the current ADA Standards for signs at exit doors.
-
1134A.7, Item 1
FIGURE 11A-9M WING WALL OR CABINET AT WATER CLOSET Exception: The 48-inch (1219 mm) minimum clear width may be reduced to 36 inches (914 mm) for lavatories, cabinets, wing walls, or...
- Accessible Mats for Beach and Outdoor Events
-
Toilet Rooms and Bathing Rooms: ADA Standard Section 213.2
Section 213.2 covers scoping requirements in the current ADA Standards for toilet rooms and bathing rooms.
-
§382.133(f)(1)
(1) Any applicable requirement for a manufacturer-affixed label to reflect that the device has been tested to meet requirements for medical portable electronic devices set by the foreign...
-
4.10.12(2)
The visual indicators shall be extinguished when each call is answered....
-
4.10.12(2)
The visual indicators shall be extinguished when each call is answered. Figure 23 Car Controls...
-
Are closet doors and pantry doors required to comply?
Doors to shallow closets or pantries, cabinets and other storage elements not providing user passage do not have to comply with provisions for doors, but must meet requirements for storage...
-
711.3.2 Membrane penetrations
Where walls and partitions are required to have a minimum 1-hour fire-resistance rating, recessed fixtures shall be installed such that the required fire resistance will not be reduced....
-
REPAIR
The definition is clear that repair is limited to work on an item or part and does not apply to a renovation, rehabilitation or renovation to an existing building in the event of fire or...