Section 236 of the 2010 Standards requires at least one of each type of exercise machine to meet clear floor space requirements of section 1004.1....
Search Results "Clear Pier Space"
-
Exercise Machines and Equipment
-
H13
Is the operating control (switch, lever, button, or pull) of at least one of each type of dispenser or built-in equipment no higher than 54 inches above the floor (if there is clear floor...
-
Turning Space: ADA Standard Section 805.2
Turning space complying with 304 shall be provided within the room....
-
Wheelchair Storage Space: ADA Standard Section 1002.6.3
Wheelchair storage spaces complying with 305 shall be provided in or adjacent to unload areas for each required transfer device and shall not overlap any required means of egress or accessible...
-
Size and Clearances [4.21.2]
Size and Clearances [4.21.2] Clear floor space is specified for side transfers. Where a forward approach is provided, space at least 60 inches wide provides room for turning....
-
11B-206.7.10 Recreational boating facilities and fishing piers and platforms
Platform lifts shall be permitted to be used instead of gangways that are part of accessible routes serving recreational boating facilities and fishing piers and platforms....
-
11B-206.7.10 Recreational boating facilities and fishing piers and platforms
Platform lifts shall be permitted to be used instead of gangways that are part of accessible routes serving recreational boating facilities and fishing piers and platforms....
-
11B-206.7.10 Recreational boating facilities and fishing piers and platforms
Platform lifts shall be permitted to be used instead of gangways that are part of accessible routes serving recreational boating facilities and fishing piers and platforms....
-
A4.22.3 Clear Floor Space
Figure 28 (section 4.16) provides minimum clear floor space dimensions for toilets in accessible “unisex” toilet rooms....
-
1011.2.2 Surface
The surface of the clear ground space shall be firm and stable....
-
1011.2.2 Surface
The surface of the clear ground space shall be firm and stable....
-
11B-604.3.1 Size
A minimum 60 inches (1524 mm) wide and 48 inches (1219 mm) deep maneuvering space shall be provided in front of the water closet....
-
Side Approach
Side Approach Clear space for a side approach is specified for units that are free-standing or built-in....
-
Gangways
Where gangways are provided as part of accessible routes to connect floating accessible fishing piers or platforms, the following exceptions to ADAAG have been included to deal with the...
-
11B-1005.2.1.1 Dispersion
Railings, guards, or handrails required to comply with Section 11B-1005.2.1 shall be dispersed throughout the fishing pier or platform. [2010 ADAS] Advisory 1005.2.1.1 Dispersion....
-
11B-1005.2.1.1 Dispersion
Railings, guards, or handrails required to comply with Section 11B-1005.2.1 shall be dispersed throughout the fishing pier or platform. Advisory 11B-1005.2.1.1 Dispersion....
-
Space
A definable area, such as a room, toilet room, hall, assembly area, entrance, storage room, alcove, courtyard, or lobby.
-
SPACE
[DSA-AC] A definable area, such as a room, toilet room, hall, assembly area, entrance, storage room, alcove, courtyard, or lobby.
-
SPACE
[DSA-AC] A definable area, such as a room, toilet room, hall, assembly area, entrance, storage room, alcove, courtyard, or lobby.
-
1015.6 Slope
The slope of the surface of clear ground spaces and turning spaces shall not be steeper than 1:48 in any direction....
-
1015.6 Slope
The slope of the surface of clear ground spaces and turning spaces shall not be steeper than 1:48 in any direction....
-
3) Where the standard says "Changes in level are not permitted", but no advisory follows the standard
404.2.4.4 floor or ground surfaces at doors: Although the Advisory at 304.2 mentions that changes in level that do not exceed those permitted in section 303.3 are acceptable in "required clear...
-
4.22.2 Doors
Doors shall not swing into the clear floor space required for any fixture....
-
4.22.2 DOORS
Doors shall not swing into the clear floor space required for any fixture....