Floor identification signs required by Chapter 10, Section 1023.9 complying with Sections 11B-703.1, 11B-703.2, 11B-703.3 and 11B-703.5 shall be located at the landing of each floor level...
Search Results "Centered Clear Floor Space"
-
11B-504.8 Floor identification
-
§ 38.23(d)(2) Location and size
The securement system shall be placed as near to the accessible entrance as practicable and shall have a clear floor area of 30 inches by 48 inches....
-
Wheelchair Transfer
The type and extent of disability, the configuration of fixtures, and the availability of space alongside water closets often determine the technique used....
-
11B-604.3.2 Overlap
clearance around the water closet shall be permitted to overlap the water closet, associated grab bars, dispensers, sanitary napkin disposal units, coat hooks, shelves, accessible routes, clear...
-
11B-604.3.2 Overlap
clearance around the water closet shall be permitted to overlap the water closet, associated grab bars, dispensers, sanitary napkin disposal units, coat hooks, shelves, accessible routes, clear...
-
§301(7)(K)
A day care center, senior citizen center, homeless shelter, food bank, adoption agency, or other social service center establishment; and...
-
11B-407.4.2 Floor surfaces
Floor surfaces in elevator cars shall comply with Section 11B-302 and 11B-303....
-
11B-407.4.2 Floor surfaces
Floor surfaces in elevator cars shall comply with Section 11B-302 and 11B-303....
- American Standard Acrylic Shroud for American Standard Selectronic Faucets
-
Seat Location: ADA Standard Section 1009.2.2
In the raised position, the centerline of the seat shall be located over the deck and 16 inches (405 mm) minimum from the edge of the pool. The deck surface between the centerline of...
-
11B-1009.2.2 Seat location
In the raised position, the centerline of the seat shall be located over the deck and 16 inches (406 mm) minimum from the edge of the pool. The deck surface between the centerline of...
-
11B-1009.2.2 Seat location
In the raised position, the centerline of the seat shall be located over the deck and 16 inches (406 mm) minimum from the edge of the pool. The deck surface between the centerline of...
-
809.2.6 Weather Alert Systems
in emergency transportable housing units, this section requires the operable parts on weather alert systems in units with mobility features to comply with the technical requirements for clear...
-
In a doctor’s office or clinic with multiple exam rooms, must every examination room have an accessible exam table and sufficient clear floor space next to the exam table?
Q In a doctor’s office or clinic with multiple exam rooms, must every examination room have an accessible exam table and sufficient clear floor space next to the exam table?...
-
Plumbing/Restrooms
PLUMBING/RESTROOMS Turning space within the room 11B-603 Door swing not in clear floor space of any fixture (except...
-
4.21.2 SIZE AND CLEARANCES
Shower stall size and clear floor space shall comply with Fig. 35(a) or (b). The shower stall in Fig. 35(a) shall be 36 in by 36 in (915 mm by 915 mm)....
-
§ 38.57(b)
route at least 32 inches wide so that at least two wheelchair or mobility aid users can enter the vehicle and position the wheelchairs or mobility aids in areas, each having a minimum clear...
-
4.21.2 Size and Clearances
Except as specified in 9.1.2, shower stall size and clear floor space shall comply with Fig. 35(a) or (b). The shower stall in Fig. 35(a) shall be 36 in by 36 in (915 mm by 915 mm)....
-
Passing Space [§403.5.3]
Passing Space [§403.5.3] Passing space is required every 200 feet and must be provided as a 60” by 60” minimum space or as T-shaped space where each stem is at least 48” long....
-
11B-403.5.2 Clear width at turn
Where the accessible route makes a 180 degree turn around an element which is less than 48 inches (1219 mm) wide, clear width shall be 42 inches (1067 mm) minimum approaching the turn, 48...
-
11B-403.5.2 Clear width at turn
Where the accessible route makes a 180 degree turn around an element which is less than 48 inches (1219 mm) wide, clear width shall be 42 inches (1067 mm) minimum approaching the turn, 48...
-
Clear Width [1016.3]
The clear width of ORARs must be a minimum of 36 inches....
-
Technical Memorandum TM 2013-16 Residential Amenity Centers
TM 2013-16 Residential Amenity Centers Effective Date: June 1, 2013 2012 TAS Reference: 68.30(5) Areas, elements, and spaces in residential amenity centers used exclusively...
-
Platform and Vehicle Floor Coordination: ADA Standard Section 810.5.3
Advisory 810.5.3 Platform and Vehicle Floor Coordination....