Diagnostic equipment that supports patients in a seated position shall comply with M302. ...
Search Results "Built-In Seating"
Commonly Searched Documents
-
M302.1 General
-
11B-502.4 Floor or ground surfaces
Built-up curb ramps are not permitted to project into access aisles and parking spaces because they would create slopes greater than 1:48....
-
11B-502.4 Floor or ground surfaces
Built-up curb ramps are not permitted to project into access aisles and parking spaces because they would create slopes greater than 1:48. ...
-
M302 Diagnostic Equipment Used by Patients in Seated Position
[See subsections ...]
-
M302 Diagnostic Equipment Used by Patients in Seated Position
[See subsections ...]
-
Purchase of multiple tickets. (Section-by-Section Analysis)
Many venues limit an individual requiring wheelchair seating to purchase no more than two tickets (for him or herself and a companion), while other patrons have significantly higher purchase...
-
M302.3.3 Head and Back Support (Section-by-Section Analysis)
In the MDE NPRM the Access Board proposed to place the requirements for head and back support for diagnostic equipment used by patients in the seated position in M302....
-
Stadium-Style Movie Theaters
must be on a riser or cross-aisle in the stadium section of the theater; and placement of such seating must satisfy at least one of the following criteria: (i) it is located within the...
-
M302.2 Transfer Surface
M302.2 Transfer Surface M302.2.3 Transfer Sides Proposed requirement: The transfer surface shall be located to provide options to transfer from a mobility device onto one...
-
ii. Accessible scales
ii. Accessible scales Medical providers often do not weigh individuals who use wheelchairs because they do not have an accessible scale, even though that information is a routine...
- Water Efficient Toilets by American Standard
- How to Remove and Install a Toilet from American Standard
- Everclean Toilets by American Standard
-
Zurn Model Z5560 Commercial EcoVantage ADA Height Elongated Toilet: Pressure-Assist Replacement Tank Kit Video
Requires the Registered User plan or above. Login!
-
608.5.3 Alternate Roll-In Type Shower Compartments
Where a seat is provided, the controls, faucets, and shower spray unit shall be located on the side wall adjacent to the seat 27 inches (685 mm) maximum from the side wall behind the seat...
-
Grab Bars [4.20.4] and Controls [4.20.5]
Tracks on the tub rim are not allowed as they can interfere with the transfer to tub seats. Dual grab bars on the back wall are needed for transfer to the seat and into the tub....
-
11B-608.5.3 Alternate roll-in type shower compartments
483 mm) maximum from the seat wall or on the back wall opposite the seat 15 inches (381 mm) maximum, left or right, of the centerline of the seat; and shall be located above the grab bar...
-
11B-608.5.3 Alternate roll-in type shower compartments
483 mm) maximum from the seat wall or on the back wall opposite the seat 15 inches (381 mm) maximum, left or right, of the centerline of the seat; and shall be located above the grab bar...
-
Wheelchair Spaces (M303.2)
M303.2 would require a wheelchair space to be provided at diagnostic equipment used by patients seated in a wheelchair....
-
608.5.3 Alternate Roll-In Type Shower Compartments
Where a seat is provided, the controls, faucets, and shower spray unit shall be located on the side wall adjacent to the seat 27 inches (685 mm) maximum from the side wall behind the seat...
-
608.5.3 Alternate Roll-In Type Shower Compartments
Where a seat is provided, the controls, faucets, and shower spray unit shall be located on the side wall adjacent to the seat 27 inches (685 mm) maximum from the side wall behind the seat...
-
11B-608.5.3 Alternate roll-in type shower compartments
wall or shall be located on the back wall opposite the seat 15 inches (381 mm) maximum, left or right of the centerline of the seat....
- American Standard Right Width 1.28-1.6 gpf FloWise Right Height Elongated Flushometer Toilet
-
5.2.3 Transfer Surface Measurement Recommendation for M301 and M302
Figure 5.2.3 below indicates how these width and depth dimensions are measured for MDE used by patients in supine, prone, or side-lying positions (M301) and the seated position (M302)...