5.8.2.6 Clearance Depth at Toe Height Above the Ground. The toe clearance depth should be 22 inches minimum at toe height.
Search Results "Tent Platform"
-
5.8.2.6 Clearance Depth at Toe Height Above the Ground
-
5.8.2.3 Overall Knee and Toe Clearance Recommendation
5.8.2.3 Overall Knee and Toe Clearance Recommendation The Committee recommends increasing the overall knee and toe space to 28 inches minimum. Rationale for the...
-
5.8.2.6 Clearance Depth at Toe Height above the ground Recommendation
5.8.2.6 Clearance Depth at Toe Height above the ground Recommendation The Committee recommends 22 inches minimum clearance depth at toe height. Rationale for...
-
5.8.2.3 Overall Knee and Toe Clearance
5.8.2.3 Overall Knee and Toe Clearance. The overall knee and toe space should be increased to a minimum of 28 inches.
-
ADA & Level Boarding - When Does Section 37.42 begin to apply?
49 CFR §37.42(a) DECEMBER 14, 2011
-
Figure M6: M303.2.4 Knee and Toe Clearance
[See subsections ...]
-
1009.1 Accessible means of egress required
Accessible means of egress shall comply with this section. Accessible spaces shall be provided with not less than one accessible means of egress. Where more than one means of egress...
-
1005.2.1 Height
At least 25 percent of the railings, guards, or handrails shall be 34 inches (865 mm) maximum above the ground or deck surface. EXCEPTION: Where a guard complying with sections...
-
1005.2.1 Height
1005.2.1 Height. At least 25 percent of the railings, guards, or handrails shall be 34 inches (865 mm) maximum above the ground or deck surface. EXCEPTION: Where a guard complying...
- CommonLook Professional Services for Electronic Accessibility of Documents and Forms
-
11B-206.6 Elevators
Exceptions: In a building or facility permitted to use the exceptions to Section 11B-206.2.3 or permitted by Section 11B-206.7 to use a platform lift, elevators complying with Section...
-
F206.7.4 Judicial Spaces
Platform lifts shall be permitted to provide an accessible route to: jury boxes and witness stands; raised courtroom stations including, judges' benches, clerks' stations, bailiffs' stations...
-
11B-206.7.4 Judicial spaces
Platform lifts shall be permitted to provide an accessible route to: jury boxes and witness stands; raised courtroom stations including, judges’ benches, clerks’ stations, bailiffs’ stations...
-
11B-206.7.4 Judicial spaces
Platform lifts shall be permitted to provide an accessible route to: jury boxes and witness stands; raised courtroom stations including, judges’ benches, clerks’ stations, bailiffs’ stations...
-
11B-206.7.4 Judicial spaces
Platform lifts shall be permitted to provide an accessible route to: jury boxes and witness stands; raised courtroom stations including, judges’ benches, clerks’ stations, bailiffs’ stations...
-
206.7.4 Judicial Spaces
Platform lifts shall be permitted to provide an accessible route to: jury boxes and witness stands; raised courtroom stations including, judges' benches, clerks' stations, bailiffs' stations...
- Microsoft Disability Answer Desk
-
206.7.4 Judicial Spaces
Platform lifts shall be permitted to provide an accessible route to: jury boxes and witness stands; raised courtroom stations including, judges' benches, clerks' stations, bailiffs' stations...
-
11B-206.6 Elevators
In a building or facility permitted to use the exceptions to Section 11B-206.2.3 _|Accessible Routes; Multi-Story Buildings and Facilities|_ or permitted by Section 11B-206.7 to use a platform...
-
11B-206.6 Elevators
In a building or facility permitted to use the exceptions to Section 11B-206.2.3 _|Accessible Routes; Multi-Story Buildings and Facilities|_ or permitted by Section 11B-206.7 to use a platform...
-
§ 37.42(b)
(b) For new or altered stations serving commuter, intercity, or high-speed rail lines or systems, in which no track passing through the station and adjacent to platforms is shared with existing...
-
§ 37.42(b)
(b) For new or altered stations serving commuter, intercity, or high-speed rail lines or systems, in which no track passing through the station and adjacent to platforms is shared with existing...
-
QUESTION: WHEN DO THE REQUIREMENTS OF SECTION 37.42 BEGIN TO APPLY?
The performance standard and other requirements of section 37.42(a) apply to stations that are approved for entry into final design or that begin construction or alteration of platforms...
-
§ 37.42(a)
37.41, an operator of a commuter, intercity, or high-speed rail system must ensure, at stations that are approved for entry into final design or that begin construction or alteration of platforms...