11B-216.4.4 Delayed egress locks
Signs required by Chapter 10, Section 1008.1.9.7, item 5.1 at doors with delayed egress locks shall comply with Sections 11B-703.1 _|Signs; General|_ 11B-703.2 _|Signs; Raised Characters...
-
11B-216.4.4 Delayed egress locks
Signs required by Chapter 10, Section 1010.1.9.7, Item 6.4 at doors with delayed egress locks shall comply with Sections 11B-703.1 _|Signs; General|_ 11B-703.2 _|Signs; Raised Characters...
-
Tactile Signage
Tactile Signage Raised and Braille characters are required on signs that "designate permanent rooms and spaces."...
-
Raised Characters: ADA Standard Section 703.2
Signs that are designed to be read by touch should not have sharp or abrasive edges. ...
-
M1
If a sign is provided at the toilet room entrance (e.g....
-
11B-216.10 Assistive listening systems
Assistive listening signs shall comply with Section 11B-703.5 _|Signs; Visual Characters|_ and shall include the International Symbol of Access for Hearing Loss complying with Section 11B...
-
11B-216.10 Assistive listening systems
Assistive listening signs shall comply with Section 11B-703.5 _|Signs; Visual Characters|_ and shall include the International Symbol of Access for Hearing Loss complying with Section 11B...
-
11B-504.8 Floor identification
It is not possible to meet the requirements for both the "Floor Identification Signs" and the "Fire Department Signs" with a single sign at each stair level, although this is frequently...
-
Mounting Location and Height [4.30.6]
Mounting Location and Height [4.30.6] Placement of tactile signs aside doors (latch-side) provides safety since locating signs on doors that swing out is hazardous....
-
11B-216.4.2 Areas of refuge and exterior areas for assisted rescue
Signs required by Chapter 10, Section 1009.11 to provide instructions in areas of refuge shall comply with Section 11B-703.5 _|Signs; Visual Characters|_....
-
PLATFORM
A temporary platform is one installed for not more than 30 days....
-
Areas of Refuge: ADA Standard Section 216.4.2
Section 216.4.2 covers scoping requirements in the current ADA Standards for signs at areas of refuge.
-
Signage
This sign must include the international symbol of access to assistive listening systems (specified in 4.30.7)....
- Seating Solutions ADA Platforms, Ramps & Stairs
-
DEFINITIONS
Someone who has only a rudimentary familiarity with sign language or finger spelling is not a "qualified sign language interpreter" under this Agreement. ...
-
Illumination Levels (Reserved) [4.30.8]
A level from 10 to 30 footcandles is recommended uniformly over the sign surface....
-
11B-504.8 Floor identification
It is not possible to meet the requirements for both the "Floor Identification Signs" and the "Fire Department Signs" with a single sign at each stair level, although this is frequently...
-
11B-504.8 Floor identification
It is not possible to meet the requirements for both the "Floor Identification Signs" and the "Fire Department Signs" with a single sign at each stair level, although this is frequently...
-
11B-216.2 Designations
Interior and exterior signs identifying permanent rooms and spaces shall comply with Sections 11B-703.1 _|Signs; General|_ 11B-703.2 _|Signs; Raised Characters|_, 11B-703.3 _|Braille|_,...
-
Scoping Requirements
Scoping requirements for signs in section 216 cover room designations, which are required to be tactile, and directional and informational signs which are not required to be tactile but...
-
11B-216.2 Designations
Interior and exterior signs identifying permanent rooms and spaces shall comply with Sections 11B-703.1 _|Signs; General|_ 11B-703.2 _|Signs; Raised Characters|_, 11B-703.3 _|Braille|_,...
-
Signage
to read a sign or they may not be able to find the sign....
-
11B-703.7.2.6 Toilet and bathing facilities geometric symbols
as at airports or stadiums, the geometric identification symbol should be located at the proper height adjacent to the opening or incorporated into the required tactile identification sign...