No, a 32-inch door would not provide a sufficient clear opening to meet the requirement for usable doors....
Search Results "Swing Clear Hinge"
-
16.1 Q. Will a standard hung 32-inch door provide sufficient clear width to meet the requirements of the Fair Housing Act?
-
Boarding Pier Clearances: ADA Standard Section 1003.3.2
Boarding piers at boat launch ramps shall provide clear pier space 60 inches (1525 mm) wide minimum and shall extend the full length of the boarding pier....
-
11B-306.2.3 Minimum required depth
Where toe clearance is required at an element as part of a clear floor space, the toe clearance shall extend 17 inches (432 mm) minimum under the element....
-
7(2)(b)
(b) Bathrooms that have reinforced walls for grab bars (see Requirement 6) would meet section 100.205(c)(3)(iv) if: Note: Clear floor space beside tub may overlap with clear floor space...
-
§ 38.83(a)(1) General
plate) complying with either paragraph (b) or (c) of this section and sufficient clearances to permit at least two wheelchair or mobility aid users to reach areas, each with a minimum clear...
-
11B-306.2.3 Minimum required depth
Where toe clearance is required at an element as part of a clear floor space, the toe clearance shall extend 17 inches (432 mm) minimum under the element. Exceptions: 1. ...
-
11B-306.2.3 Minimum required depth
Where toe clearance is required at an element as part of a clear floor space, the toe clearance shall extend 17 inches (432 mm) minimum under the element....
-
11B-804.6.3 Dishwasher
Clear floor or ground space shall be positioned adjacent to the dishwasher door....
-
804.6.3 Dishwasher
Clear floor or ground space shall be positioned adjacent to the dishwasher door....
-
11B-804.6.3 Dishwasher
Clear floor or ground space shall be positioned adjacent to the dishwasher door....
-
11B-804.6.3 Dishwasher
Clear floor or ground space shall be positioned adjacent to the dishwasher door....
-
804.6.3 Dishwasher
Clear floor or ground space shall be positioned adjacent to the dishwasher door....
-
11B-1003.3.2 Boarding pier clearances
Boarding piers at boat launch ramps shall provide clear pier space 60 inches (1524 mm) wide minimum and shall extend the full length of the boarding pier....
-
11B-1003.3.2 Boarding pier clearances
Boarding piers at boat launch ramps shall provide clear pier space 60 inches (1524 mm) wide minimum and shall extend the full length of the boarding pier....
-
804.6.3 Dishwasher
Clear floor or ground space shall be positioned adjacent to the dishwasher door....
-
4.5.2.1 Forward Approach
The clear floor or ground space for a forward approach shall be 36 inches (915 mm) by 48 inches (1220 mm)....
-
4.5.2.2 Side Approach
The clear floor or ground space for a side approach shall be 30 inches (760 mm) by 60 inches (1525 mm)....
-
902.2 Clear Floor or Ground Space
902.2 Clear Floor or Ground Space. A clear floor space complying with 305 positioned for a forward approach shall be provided. Knee and toe clearance complying...
-
1011.2.1 Size and Location
This section specifies the size and location of the clear ground space at outdoor constructed features....
-
1132A.3, Item 2
Swinging doors shall provide a net clear opening width of not less than 32 inches (813 mm), measured with the door or doors positioned at an angle of 90 degrees from the closed position....
-
1132A.3, Item 2
Swinging doors shall provide a net clear opening width of not less than 32 inches (813 mm), measured with the door or doors positioned at an angle of 90 degrees from the closed position....
-
Turning Space [§304]
Clear Width at 180 Degree Turn Around a Narrow Obstruction Recommendation: Turning space is recommended in small spaces with entrapment risks as well as at dead-end aisles...
-
1008.2.4.1 Ground Level
At ground level, the clear width of accessible routes shall be 60 inches (1525 mm) minimum. EXCEPTIONS: 1....
-
11B-1008.2.4.1 Ground level