Alcoves shall be 36 inches (915 mm) wide minimum where the depth exceeds 24 inches (610 mm).
Search Results "Swing Clear Hinge"
-
305.7.1 Forward Approach
-
305.7.1 Forward Approach
305.7.1 Forward Approach. Alcoves shall be 36 inches (915 mm) wide minimum where the depth exceeds 24 inches (610 mm). Figure 305.7.1 Maneuvering Clearance in an Alcove,...
-
305.7.2 Parallel Approach
305.7.2 Parallel Approach. Alcoves shall be 60 inches (1525 mm) wide minimum where the depth exceeds 15 inches (380 mm). Figure 305.7.2 Maneuvering Clearance in an Alcove,...
- 305.3 Package Drop Box Clear Floor Space
- Figure 1003.3.1 (Exception 1) Clear Pier Space Reduction at Boat Slips – Drawing from the U.S. Access Board
- Figure 1003.3.2 (Exception 1) Clear Pier Space Reduction at Boarding Piers – Drawing from the U.S. Access Board
-
Beds: ADA Standard Section 224.3
Section 224.3 covers scoping requirements in the current ADA Standards for transient lodging guest room beds.
-
Width and Length
The wall must be a minimum of 60 inches long and must be centered on the clear deck space. Additional length will provide increased space and options for transferring....
-
4.5.6 Openings
Openings in the clear floor or ground space surface shall not allow passage of a sphere more than 1/2 inch (13 mm) diameter....
-
Surface and Clear Tread Width on Beach Access Routes
A beach access route must have a firm, stable surface, and have a clear tread width of 60 inches (1,525 millimeters) minimum....
-
11B-224.3 Beds
In guest rooms having more than 25 beds, 5 percent minimum of the beds shall have clear floor space complying with Section 11B-806.2.3....
-
11B-224.3 Beds
In guest rooms having more than 25 beds, 5 percent minimum of the beds shall have clear floor space complying with Section 11B-806.2.3....
-
3.4.7 Openings
Openings in the clear ground space and turning space surface shall not allow passage of a sphere more than 1/2 inch (13 mm) diameter....
-
5.3.2.3 Slope
The slope of the turning space and clear floor or ground space surface shall not be steeper than 1:48 (2 percent) in all directions....
- Landscape Forms Inc. Central Park Conservancy Recycling System
-
1016.4 Passing Spaces
Outdoor recreation access routes with a clear width less than 60 inches (1525 mm) shall provide passing spaces complying with 1016.4 at intervals of 200 feet (61 m) maximum. ...
-
1016.4 Passing Spaces
Outdoor recreation access routes with a clear width less than 60 inches (1525 mm) shall provide passing spaces complying with 1016.4 at intervals of 200 feet (61 m) maximum....
-
1008.2.6 Ground Surfaces
Ground surfaces on accessible routes, clear floor or ground spaces, and turning spaces shall comply with 1008.2.6. Advisory 1008.2.6 Ground Surfaces....
-
R405.1 General
Where space beneath an element is included as part of a clear space, the space shall comply with R405....
-
1008.2.6 Ground Surfaces
Ground surfaces on accessible routes, clear floor or ground spaces, and turning spaces shall comply with 1008.2.6. Advisory 1008.2.6 Ground Surfaces....
-
Plan 3A: 12-Foot Wide Accessible Guest Room
607.2); • Recessed lavatory with vanity countertop permits shorter rear grab bar at water closet (section 604.5.2); • Circular turning space in room (section 603.2.1); • Required clear...
- Landscape Forms Inc. Select Modular Steel Recycling Units
- Neo-Metro Urinal Divider Number 8949-N
-
16.1 Q. Will a standard hung 32-inch door provide sufficient clear width to meet the requirements of the Fair Housing Act?
No, a 32-inch door would not provide a sufficient clear opening to meet the requirement for usable doors....