., a driveway or sidewalk) with the passenger's wheeled device should generally be granted....
Search Results "Sloped Sidewalk"
Commonly Searched Documents
-
22. Navigating an Incline, or Around Obstacles
-
5. Safety Hazards
and implemented "effective policies for the identification and prompt removal of safety hazards, it is likely that [she] would not have encountered steep paths of travel and entrances, sidewalks...
-
Gangway
A variable-sloped pedestrian walkway that links a fixed structure or land with a floating structure. Gangways that connect to vessels are not addressed by this document....
-
BOAT LAUNCH RAMP
[DSA-AC] A sloped surface designed for launching and retrieving trailered boats and other water craft to and from a body of water....
-
PATH OF TRAVEL
existing site, building or facility by means of which a particular area may be approached, entered and exited, and which connects a particular area with an exterior approach (including sidewalks...
-
11B-810.5.3 Platform and vehicle floor coordination
Exception: Where vehicles are boarded from sidewalks or street-level, low-level platforms shall be permitted to be less than 8 inches (203 mm). U.S....
-
1.7 Procedure
Two “blank” trials were also inserted for each of the sidewalks (except the brick sidewalk) for a grand total of 58 trials....
-
GANGWAY
[DSA-AC] A variable-sloped pedestrian walkway that links a fixed structure or land with a floating structure. Gangways that connect to vessels are not addressed by this code....
-
A. Background
Curb ramps are a small but important part of making sidewalks, street crossings, and the other pedestrian routes that make up the public right-of-way accessible to people with disabilities...
-
Executive Summary
Each background was 1.22 m (4 ft) wide by 2.44m (8 ft) long and was constructed to simulate the appearance of a red brick sidewalk, a dark gray asphalt sidewalk, a white concrete sidewalk...
-
Definition [F106.5]
The Access Board is developing accessibility guidelines for sidewalks and shared-use paths....
-
11B-106.5 Defined terms
POOL CCR CHARACTERS CHILDREN’S USE CIRCULATION PATH CLEAR CLEAR FLOOR SPACE CLOSED-CIRCUIT TELEPHONE COMMERCIAL FACILITIES COMMON USE COMPLY WITH CROSS SLOPE...
-
CIRCULATION PATH
[DSA-AC] An exterior or interior way of passage provided for pedestrian travel, including but not limited to, walks, sidewalks, hallways, courtyards, elevators, platform lifts, ramps, stairways...
-
Turning Space: ADA Standard Section 1010.1
A circular turning space 60 inches (1525 mm) diameter minimum with slopes not steeper than 1:48 shall be provided at shooting facilities with firing positions....
-
11B-1010.1 Turning space
A circular turning space 60 inches (1524 mm) diameter minimum with slopes not steeper than 1:48 shall be provided at shooting facilities with firing positions....
-
11B-809.8.1 Door Thresholds
Secondary exterior door thresholds, including sliding door tracks, shall be 3/4 inch (19.1 mm) high maximum with a 1:2 maximum slope....
-
3.1 Key Findings
Detectable warnings that are the same color as the sidewalk or very similar in color to the sidewalk could not be seen by most participants in this study....
-
OTHER SPECIFIC BARRIERS
Some of the barriers identified in Exhibit A are so severe that they constitute safety hazards to persons with mobility disabilities, including curb ramps with running slopes greater than...
-
Typical Issues
The access aisle may be at the street level or at sidewalk level. If it is at the sidewalk level, a curb ramp is provided between the street and the sidewalk....
-
2.7 Comparing Visual Detection Rates and High Conspicuity Ratings for Detectable Warnings
The percentages of participants giving high conspicuity ratings for each detectable warning by sidewalk combination are shown in Table 14....
- Armor-Tile Tactile Systems Detectable Directional System
-
Start of Play: ADA Standard Section 1007.3.1
A clear floor or ground space 48 inches (1220 mm) minimum by 60 inches (1525 mm) minimum with slopes not steeper than 1:48 shall be provided at the start of play....
-
11B-1007.3.1 Start of play
A clear floor or ground space 48 inches (1219 mm) minimum by 60 inches (1524 mm) minimum with slopes not steeper than 1:48 shall be provided at the start of play....
-
2. Electronic (Digital) Level
Even experts can misjudge how steep a running slope or cross slope is if they do not use a level....