Turning Space [§304] Turning space is required in these accessible rooms and spaces: toilet and bathing facilities dressing, fitting, and locker rooms transient...
Search Results "Sign Clear Floor Space"
-
Turning Space [§304]
-
7(2)(b)(vi)
(vi) Bathtubs and tub/showers located in the bathroom provide a clear access aisle adjacent to the lavatory that is at least 2'6" wide and extends for a length of 4'0" (measured from the...
- Bobrick Accessibility Video -- Design for Turning Radiuses
-
31.1 Q. Can a water closet (toilet) be located in an alcove with a wing wall?
Yes, as long as the necessary clear floor space shown in Figure 7(a) is provided....
- Figure 1009.4.3 Depth and Length of Tranfer Walls – Drawing from the U.S. Access Board
-
407.2.3 Hoistway Signs
Signs at elevator hoistways shall comply with 407.2.3....
-
407.2.3 Hoistway Signs
Signs at elevator hoistways shall comply with 407.2.3....
-
1134A.7, Item 1
Floor space and location. The minimum floor space provided at a water closet shall be 48 inches (1219 mm) in clear width....
-
608.2.2.1 Clearance
A 30 inch (760 mm) wide minimum by 60 inch (1525 mm) long minimum clearance shall be provided adjacent to the open face of the shower compartment. EXCEPTION: A lavatory complying...
-
Obstructions
Obstructions “Obstructions” are also prohibited by TAS 604.3.2 within the required water closet clearance. An obstruction is any element that violates the protruding object...
-
608.2.2.1 Clearance
A 30 inch (760 mm) wide minimum by 60 inch (1525 mm) long minimum clearance shall be provided adjacent to the open face of the shower compartment. EXCEPTION: A lavatory complying...
-
608.2.2.1 Clearance
608.2.2.1 Clearance. A 30 inch (760 mm) wide minimum by 60 inch (1525 mm) long minimum clearance shall be provided adjacent to the open face of the shower compartment. EXCEPTION:...
-
Figure 11B-407.2.3.1 Floor designation
SECTION TITLE NOTES Figure 11B-407.2.3.1 Floor designation....
-
1134A.7, Item 1
Floor space and location. The minimum floor space provided at a water closet shall be 48 inches (1219 mm) in clear width. ...
-
3.4.6 Surface
The surface of each viewing area shall be firm and stable. The type of surface should be appropriate to the setting and level of development.
- Behavioral Safety Products #TC230 Suicide Resistant Standard Trap Cover
- McGuire Manufacturing Co., Inc. 155CRSWC: Offset Lavatory Strainer with Chain and Rubber Stopper
-
Wheelchair Spaces
Wheelchair Spaces Maneuvering into wheelchair spaces is often easier from the front or back than from the side, especially where they are paired....
-
804.6.4 Range or Cooktop
Where a forward approach is provided, the clear floor or ground space shall provide knee and toe clearance complying with 306....
-
804.6.4 Range or Cooktop
Where a forward approach is provided, the clear floor or ground space shall provide knee and toe clearance complying with 306....
-
GROUND FLOOR
[DSA-AC] The floor of a building with a building entrance on an accessible route. A building may have one or more ground floors....
-
GROUND FLOOR
[DSA-AC] The floor of a building with a building entrance on an accessible route. A building may have one or more ground floors....
-
11B-804.6.4 Range or cooktop
Where a forward approach is provided, the clear floor or ground space shall provide knee and toe clearance complying with Section 11B-306....