Search Results "Security System"
- TelCom Red Wall Mount Weatherproof Audible Horn Strobe - 180 cd ASWP-2475W-FR
-
11B-232.2.2 Cells with communication features
At least 2 percent, but no fewer than one, of the total number of general holding cells and general housing cells equipped with audible emergency alarm systems and permanently installed...
-
11B-232.2.2 Cells with communication features
At least 2 percent, but no fewer than one, of the total number of general holding cells and general housing cells equipped with audible emergency alarm systems and permanently installed...
- inLOOP Commercial Use Loop Listener #01115
-
706.6 Peak Clipping Level
Peak clipping shall not exceed 18 dB of clipping relative to the peaks of speech. [ECTCR UFAS 4.33.7]
-
708.3 Handsets
Handset cords, if provided, shall be 29 inches (735 mm) long minimum.
-
ยง382.83 Through what mechanisms do carriers make seating accommodations?
[See subsections ...]
-
11B-706.6 Peak clipping level
Peak clipping shall not exceed 18 dB of clipping relative to the peaks of speech.
-
382.83 Through what mechanisms do carriers make seating accommodations?
382.83 Through what mechanisms do carriers make seating accommodations? ETA Editor's Note This section has no content in the original document.
-
11B-708.3 Handsets
Handset cords, if provided, shall be 29 inches (737 mm) long minimum.
-
708.3 Handsets
Handset cords, if provided, shall be 29 inches (735 mm) long minimum.
-
706.6 Peak Clipping Level
Peak clipping shall not exceed 18 dB of clipping relative to the peaks of speech.
-
Requirements to Remember for: Light Rail Projects
[See subsections ...]
-
706.6 Peak Clipping Level
706.6 Peak Clipping Level. Peak clipping shall not exceed 18 dB of clipping relative to the peaks of speech.
-
Sec. 12143. Paratransit as a complement to fixed route service. [Section 223]
[See subsections ...]
-
708.3 Handsets
708.3 Handsets. Handset cords, if provided, shall be 29 inches (735 mm) long minimum.
-
4.28.3(3)
(3) The maximum pulse duration shall be two-tenths of one second (0.2 sec) with a maximum duty cycle of 40 percent. The pulse duration is defined as the time interval between initial...
-
4.3.11.4* Two-way Communication
A method of two-way communication, with both visible and audible signals, shall be provided between each area of rescue assistance and the primary entry. The fire department or...
-
A4.28 Alarms
[See subsections ...]
-
Location and Spacing
Location and Spacing Rooms with an area than can be circumscribed by a circle 50 feet in radius can be covered by a single centrally located strobe of 75 cd. For very small rooms,...
-
A4.28.2 Audible Alarms
Audible emergency signals must have an intensity and frequency that can attract the attention of individuals who have partial hearing loss. People over 60 years of age generally have...
-
4.28.3(5)
(5) The flash rate shall be a minimum of 1 Hz and a maximum of 3 Hz.
-
Mounting Height
Mounting Height ADAAG specifies a signal height 80 inches above the highest floor level within the space or 6 inches below the ceiling, whichever is lower. (This can be measured...
-
4.28 Alarms
[See subsections ...]