Objects are permitted to protrude a distance of 6 inches (150 mm) maximum along the front of the wheelchair space, where located 9 inches (230 mm) minimum and 27 inches (685 mm) maximum...
Search Results "Maximum Extent Practicable"
-
Permitted Protrusions in Wheelchair Spaces: ADA Standard Section 1002.4.4.3
-
11B-1002.4.4.3 Permitted protrusions in wheelchair spaces
Objects are permitted to protrude a distance of 6 inches (152 mm) maximum along the front of the wheelchair space, where located 9 inches (229 mm) minimum and 27 inches (686 mm) maximum...
-
11B-608.7 Thresholds
Thresholds in roll-in type shower compartments shall be ½ inch (12.7 mm) high maximum in accordance with Section 11B-303....
-
11B-607.4.2.1 Back wall
Two grab bars shall be installed on the back wall, one located in accordance with Section 11B-609.4 and the other located 8 inches (203 mm) minimum and 10 inches (254 mm) maximum above the...
-
11B-608.7 Thresholds
Thresholds in roll-in type shower compartments shall be ½ inch (12.7 mm) high maximum in accordance with Section 11B-303....
-
11B-607.4.2.1 Back wall
Two grab bars shall be installed on the back wall, one located in accordance with Section 11B-609.4 and the other located 8 inches (203 mm) minimum and 10 inches (254 mm) maximum above the...
-
11B-1002.4.4.3 Permitted protrusions in wheelchair spaces
Objects are permitted to protrude a distance of 6 inches (152 mm) maximum along the front of the wheelchair space, where located 9 inches (229 mm) minimum and 27 inches (686 mm) maximum...
-
Title II Public Entity Facilities Compliance Timetable
Begin self-evaluation process for those areas of services, policies and practices not previously evaluated (and on file) for section 504 of the Rehabilitation Act of 1973. (35.105) B....
-
11B-303.2 Vertical
Changes in level of ¼ inch (6.4 mm) high maximum shall be permitted to be vertical and without edge treatment. [2010 ADA Standards] 303.2 Vertical....
-
11B-303.2 Vertical
Changes in level of ¼ inch (6.4 mm) high maximum shall be permitted to be vertical and without edge treatment. [2010 ADA Standards] 303.2 Vertical....
-
R202 Alterations and Elements Added to Existing Facilities (Section-by-Section Analysis)
practicable within the scope of the project....
-
Sec.36.401(c)(2)
(2) If full compliance with this section would be structurally impracticable, compliance with this section is required to the extent that it is not structurally impracticable....
-
203.15.2
203.15.2 If full compliance with this section would be structurally impracticable, compliance with this section is required to the extent that it is not structurally impracticable....
-
§ 35.151(a)(2)(ii)
(ii) If full compliance with this section would be structurally impracticable, compliance with this section is required to the extent that it is not structurally impracticable. ...
-
§ 36.401(c)(2)
(2) If full compliance with this section would be structurally impracticable, compliance with this section is required to the extent that it is not structurally impracticable....
-
§ 37.41(b)(2)
(2) If full compliance with this section would be structurally impracticable, compliance with this section is required to the extent that it is not structurally impracticable....
-
§ 35.151(a)(2)(ii)
(ii) If full compliance with this section would be structurally impracticable, compliance with this section is required to the extent that it is not structurally impracticable....
-
702 Fire Alarm Systems
permits fire alarm systems to be provided in accordance with industry practice....
-
Special Holding Cells and Special Housing Cells: ADA Standard Section 232.3
Section 232.3 covers scoping requirements in the current ADA Standards for special holding cells and special housing cells.
-
Non-Circular Cross Section: ADA Standard Section 609.2.2
Section 609.2.2 covers the current ADA Standards for non-circular grab bar cross sections.
-
11B-609.2.2 Non-circular cross section
Grab bars with non-circular cross sections shall have a cross-section dimension of 2 inches (51 mm) maximum and a perimeter dimension of 4 inches (102 mm) minimum and 4.8 inches (122 mm)...
-
11B-609.2.2 Non-circular cross section
Grab bars with non-circular cross sections shall have a cross-section dimension of 2 inches (51 mm) maximum and a perimeter dimension of 4 inches (102 mm) minimum and 4.8 inches (122 mm)...
-
Dispensers: ADA Standard Section 604.7
Section 604.7 covers the current ADA Standards for toilet paper dispensers.
-
Non-Circular Cross Sections: ADA Standard Section 505.7.2
Section 505.7.2 covers the current ADA Standards for the non-circular cross section of handrail gripping surfaces.