If seating for people in wheelchairs is provided at tables or counters, knee spaces at least 27 in (685 mm) high, 30 in (760 mm) wide, and 19 in (485 mm) deep shall be provided (see Fig....
Search Results "High Drinking Fountain"
-
4.32.3 Knee Clearances
-
308.2.1 Unobstructed
Where a forward reach is unobstructed, the high forward reach shall be 48 inches (1220 mm) maximum and the low forward reach shall be 15 inches (380 mm) minimum above the finish floor or...
-
11B-308.2.1 Unobstructed
Where a forward reach is unobstructed, the high forward reach shall be 48 inches (1219 mm) maximum and the low forward reach shall be 15 inches (381 mm) minimum above the finish floor or...
-
11B-308.2.1 Unobstructed
Where a forward reach is unobstructed, the high forward reach shall be 48 inches (1219 mm) maximum and the low forward reach shall be 15 inches (381 mm) minimum above the finish floor or...
-
H8
If lavatories are provided, does at least one have at least a 29 inch high clearance under the front apron with the top of the rim no more than 34 inches above the floor?...
-
§ 37.42(e)(1)
(1) Except as provided in paragraph (e)(2) of this paragraph, any obstructions on a platform (mini-high platforms, stairwells, elevator shafts, seats etc.) shall be set at least six feet...
-
A4.13.11(3) Application of force
In high-rise buildings, air-pressure differentials may require a modification of this specification in order to meet the functional intent....
-
4.8.7 Edge Protection
Curbs shall be a minimum of 2 in (50 mm) high (see Fig. 17)....
-
4.8.7 EDGE PROTECTION
Curbs shall be a minimum of 2 in (50 mm) high (see Fig. 17)....
-
A4.13.11(3) Application of force
In high-rise buildings, air-pressure differentials may require a modification of this specification in order to meet the functional intent....
-
§ 37.42(e)(1)
(1) Except as provided in paragraph (e)(2) of this paragraph, any obstructions on a platform (mini-high platforms, stairwells, elevator shafts, seats etc.) shall be set at least six feet...
-
8.8 Pre-Employment Inquiries About Drug and Alcohol Use
An employer may ask whether an applicant drinks alcohol or whether he or she is currently using drugs illegally....
-
4.32.3 KNEE CLEARANCES
If seating for people in wheelchairs is provided at tables, counters, and work surfaces, knee spaces at least 27 in (685 mm) high, 30 in (760 mm) wide, and 19 in (485 mm) deep shall be provided...
-
11B-703.8.1 General
High resolution variable message sign (VMS) characters shall comply with Sections 11B-703.5 and 11B-703.8.12 through 11B-703.8.14....
-
M301.2.1 Adjustability (Section-by-Section Analysis)
the Access Board has renamed this provision and now requires the transfer surface height to be adjustable to: (1) a low transfer height of 17 inches minimum and 19 inches maximum; (2) a high...
-
L. Lavatory
Is there at least one lavatory (wash basin) in each public restroom that has each of the following characteristics... ...a 29" high clearance under the front edge and the top of the bowl...
-
Road Racing Wheelchairs
Most chairs also have hand brakes to assist in stopping at high speeds. A steering mechanism compensates for the crown of the road so that the athlete can push equally with both arms....
-
1i
Are all of the small showers free of curbs or lips greater than 1/2" high at the shower floor that would impede wheelchair approach and transfer onto the folding shower seat?...
-
D. Sign Height
Does each accessible parking space have a post- or wall-mounted sign with the symbol of accessibility mounted high enough so the sign is visible when a vehicle is parked in the space?...
-
§ 37.42(e)
(e) In any situation using a combination of high and low platforms, a commuter or intercity rail operator shall not employ a solution that has the effect of channeling passengers into a...
-
§ 37.42(e)
(e) In any situation using a combination of high and low platforms, a commuter or intercity rail operator shall not employ a solution that has the effect of channeling passengers into a...
-
Mary Ann Hay, IALD, LEED AP, Vice President, Director, Architectural Lighting Design, Syska Hennessy Group, Inc.
Discomfort Glare (slide 4) Definition: A sensation of irritation or pain from high luminances in the field of view Sources of Discomfort Glare: High luminance sources....
-
General: ADA Standard Section 308.1
Section 308.1: of the ADA Standards covers information in the current ADA Standards for reach ranges.
-
11B-308.1 General
Children's Reach Ranges Forward or Side Reach Ages 3 and 4 Ages 5 through 8 Ages 9 through 12 High...