Requirement: 4.1.3(16)(a) Signs which designate permanent rooms and spaces shall comply with 4.30.1, 4.30.4, 4.30.5 and 4.30.6. 4.30.6 Mounting Location and Height....
Search Results "Handrail Height"
Commonly Searched Documents
-
Signage
-
Sales and Service Counters, Teller Windows, Information Counters [7.2]
Sales and Service Counters, Teller Windows, Information Counters [7.2] ADAAG generally specifies accessible counter heights up to 34 inches [4.32] but allows a height up to 36 inches...
-
1134A.8, Item 1
1. Location. Vanities and lavatories shall be installed with the centerline of the fixture a minimum of 18 inches (457 mm) horizontally from an adjoining wall or fixture to...
-
4. Grab Bars
4. Does the toilet in each accessible guestroom bathroom have a horizontal grab bar along the adjacent side wall that is at least 42" long and mounted 33"-36" above the floor for...
-
E. Grab Bars
E. Does each accessible toilet have a horizontal grab bar on the adjacent side wall that is at least 40" long and between 33"-36" above the floor for stabilization and assistance...
-
F. Grab Bars
F. Does each accessible toilet have a horizontal grab bar on the wall behind the toilet that is at least 36" long and between 33"-36" above the floor for stabilization and assistance...
-
5. Grab Bars
5. Does the accessible toilet in each accessible guestroom bathroom have a horizontal grab bar along the wall behind the toilet that is at least 36" long and mounted 33"-36" above...
-
1134A.8, Item 1
1. Location. Vanities and lavatories shall be installed with the centerline of the fixture a minimum of 18 inches (457 mm) horizontally from an adjoining wall or fixture to allow for...
-
§ 38.75(c)
(c) Characters on signs required by paragraphs (a) or (b) of this section shall have a width-to-height ratio between 3:5 and 1:1 and a stroke width-to-height ratio between 1:5 and 1:10,...
-
M305.2.3 Height (Section-by-Section Analysis)
In the MDE NPRM there was no specific requirement regarding the height of the transfer support, only that it be “within reach” of the patient (proposed M305.2.1)....
-
1002.2 Accessible Routes
In load or unload areas and on amusement rides, handrails provided along walking surfaces complying with 403 and required on ramps complying with 405 shall not be required to comply with...
-
1002.2 Accessible Routes
In load or unload areas and on amusement rides, handrails provided along walking surfaces complying with 403 and required on ramps complying with 405 shall not be required to comply with...
-
1002.2 Accessible Routes
In load or unload areas and on amusement rides, handrails provided along walking surfaces complying with 403 and required on ramps complying with 405 shall not be required to comply with...
-
11B-1002.2 Accessible routes
In load or unload areas and on amusement rides, handrails provided along walking surfaces complying with Section 11B-403 and required on ramps complying with Section 11B-405 shall not be...
-
11B-1002.2 Accessible routes
In load or unload areas and on amusement rides, handrails provided along walking surfaces complying with Section 11B-403 and required on ramps complying with Section 11B-405 shall not be...
-
11B-1002.2 Accessible routes
. ◼ In load or unload areas and on amusement rides, handrails provided along walking surfaces complying with Section 11B-403 and required on ramps complying with Section 11B...
-
Section G: Ramps
(§405.3) G3 Is the rise (height) for any ramp run 30" or less?...
- UpScale by Medical Accessibility - Adjustable Height Exam Table with Built-in Scale
-
11B-703.5.6 Height from finish floor or ground
11B-703.5.6 Height from finish floor or ground. Visual characters shall be 40 inches (1016 mm) minimum above the finish floor or ground. Exceptions: 1....
-
11B-216.2 Designations
at the door to the space that they serve, but this is inferable from the fact that the requirement for braille is contained within 11B-703.2, as are the requirements pertaining to the height...
-
Identification: ADA Standard Section 502.6
Section 502.6 covers the current ADA Standards for parking space identification signs.
-
Characters: ADA Standard Section 707.7.2
Characters displayed on the screen shall be in a sans serif font. Characters shall be 3/16 inch (4.8 mm) high minimum based on the uppercase letter "I". Characters shall contrast...
-
5.4.3 Transfer Support Height for M301 and M302
The purpose of a minimum height is to ensure that the gripping surface is at an adequate height to facilitate positioning during a transfer....