., concrete, brick, flagstone) serving primary entry doors and required exit doors are limited to not more than ½ inch (12.7 mm) of change in height between floor surfaces....
Search Results "Ground Floor Exit"
-
1132A.4, Item 1
-
A4.3.11.3 Stairway Width
A 48 in (1220 mm) wide exit stairway is needed to allow assisted evacuation (e.g., carrying a person in a wheelchair) without encroaching on the exit path for ambulatory persons....
-
703.4.2 Location
Signs containing tactile characters shall be located so that a clear floor space of 18 inches (455 mm) minimum by 18 inches (455 mm) minimum, centered on the tactile characters, is provided...
-
602.2 Clear Floor Space
Units shall have a clear floor or ground space complying with 305 positioned for a forward approach and centered on the unit....
-
907.2.9 Group R-2
A fire alarm system shall be installed in Group R-2 occupancies where: Any dwelling unit is located three or more stories above the lowest level of exit discharge; Any...
-
703.4.2 Location
Signs containing tactile characters shall be located so that a clear floor space of 18 inches (455 mm) minimum by 18 inches (455 mm) minimum, centered on the tactile characters, is provided...
-
703.4.2 Location
Signs containing tactile characters shall be located so that a clear floor space of 18 inches (455 mm) minimum by 18 inches (455 mm) minimum, centered on the tactile characters, is provided...
-
11B-707.2 Clear floor or ground space
11B-707.2 Clear floor or ground space. A clear floor or ground space complying with Section 11B-305 shall be provided....
-
602.2 Clear Floor Space
Units shall have a clear floor or ground space complying with 305 positioned for a forward approach and centered on the unit....
-
11B-611.2 Clear Floor Space
11B-611.2 Clear Floor Space. A clear floor or ground space complying with Section 11B-305 positioned for parallel approach shall be provided....
-
410.3 Clear Floor Space
410.3 Clear Floor Space. Clear floor space in platform lifts shall comply with 305....
-
1008.2.5.1 Ground Level
Ramp runs connecting ground level play components shall have a running slope not steeper than 1:16....
-
1008.2.5.1 Ground Level
Ramp runs connecting ground level play components shall have a running slope not steeper than 1:16....
-
Carpet: ADA Standard Section 302.2
Section 302.2 covers the current ADA Standards for carpet.
-
1004.1 Clear Floor Space
Clear floor or ground spaces required at exercise machines and equipment shall be permitted to overlap. Advisory 1004.1 Clear Floor Space....
-
1004.1 Clear Floor Space
Clear floor or ground spaces required at exercise machines and equipment shall be permitted to overlap. Advisory 1004.1 Clear Floor Space....
-
Common Questions (Clear Floor or Ground Space and Turning Space)
Common Questions
-
11B-904.4.1 Parallel approach
A portion of the counter surface that is 36 inches (914 mm) long minimum and 34 inches (864 mm) high maximum above the finish floor shall be provided....
-
11B-904.4.1 Parallel approach
A portion of the counter surface that is 36 inches (914 mm) long minimum and 34 inches (864 mm) high maximum above the finish floor shall be provided....
-
1004.1 Clear Floor Space
1004.1 Clear Floor Space. Exercise machines and equipment shall have a clear floor space complying with 305 positioned for transfer or for use by an individual seated in a wheelchair....
-
Maximum Slope at Ground Level
Maximum Slope at Ground Level The maximum allowable slope for a ground-level accessible route is 1:16. Berms are sometimes used to provide access to elevated play areas....
-
11B-611.2 Clear Floor Space
A clear floor or ground space complying with Section 11B-305 positioned for parallel approach shall be provided. The clear floor or ground space shall be centered on the appliance....
-
11B-611.2 Clear Floor Space
A clear floor or ground space complying with Section 11B-305 positioned for parallel approach shall be provided. The clear floor or ground space shall be centered on the appliance....
-
1009.3 Stairways
[DSA·AC & HCD 1-AC] In addition, exit stairways shall comply with Chapter 11A, Sections 1115A and 1123A, or Chapter 11B, Sections 11B-210 and 11B-504, as applicable....