The floor or landing on the dwelling unit side of the primary entry door and any required exit door shall have a minimum length of not less than 44 inches (1118 mm)....
Search Results "Doors in Series"
-
1132A.5.1 General
-
11B-813.2.10 Door swing
A door, in any position, shall be permitted to encroach into the turning space by 12 inches (305 mm) maximum....
-
Scoping [4.1.3(7)]
Scoping [4.1.3(7)] Doors required to be accessible include: at least one door at each accessible entrance at least one door at each accessible space within a building...
-
603.2.3 Door Swing
603.2.3 Door Swing. Doors shall not swing into the clear floor space or clearance required for any fixture. Doors shall be permitted to swing into the required turning space....
-
1132A.4 Level floor or landing
The floor or landing on each side of a door shall be level....
-
Opening Doors From a Wheelchair Video
Requires the Registered User plan or above. Login!
-
1010.1.5 Floor elevation
There shall be a floor or landing on each side of a door. Such floor or landing shall be at the same elevation on each side of the door....
-
11B-809.8.3.1 Floor or ground surface
Exceptions: The floor or landing at primary entry doors, required exit doors and secondary exit doors where a change in elevation occurs between the interior and the exterior surface of...
-
603.2.3 Door Swing
Doors shall not swing into the clear floor space or clearance required for any fixture. Doors shall be permitted to swing into the required turning space. EXCEPTIONS: 1....
-
603.2.3 Door Swing
Doors shall not swing into the clear floor space or clearance required for any fixture. Doors shall be permitted to swing into the required turning space. EXCEPTIONS: 1....
-
1132A.4 Level floor or landing
The floor or landing on each side of a door shall be level....
-
§ 38.123(a)(5)
Door latches and hardware shall be operable with one hand and shall not require tight grasping, pinching, or twisting of the wrist....
-
Doorways
In transient lodging facilities, doors and doorways in inaccessible guest rooms are required to be at least 32 inches wide (224.1.2)....
- Norton Surface Mounted Heavy Duty 9500 Series Door Closer
- Allegion Falcon SC80 Series Surface Mounted Door Control
-
603.2.3 Door Swing
Doors shall not swing into the clear floor space or clearance required for any fixture. Doors shall be permitted to swing into the required turning space. EXCEPTIONS: 1....
-
4.1.6(3)(c)(i)
(i) If safety door edges are provided in existing automatic elevators, automatic door reopening devices may be omitted (see 4.10.6)....
-
1132A.4 Level floor or landing
The floor or landing on each side of a door shall be level....
-
§ 38.93(c) Signals
If doors to the platform close automatically or from a remote location, auditory and visual warning signals shall be provided to alert passengers or closing doors....
-
1004.2.1 Exit or exit access doorways required
Exception: Exit access doors required by Section 1004.2.3.2 for Group I-2 occupancies....
-
11B-405.7.5 Doorways
Advisory 11B-405.7.5 Doors at ramp landings....
- TownSteel Resetting factory mode for XCE XME 2000 series
-
Automatic and Power-Assisted Doors and Gates [§404.3]
Automatic and Power-Assisted Doors and Gates [§404.3] Doors are not required to be automated, but must comply when provided....
-
§ 38.157(b)
(b) The vehicle doorway shall have outside light(s) which, when the door is open, provide at least 1 foot-candle of illumination on the pathway to the door for a distance of 3 feet (915...
