. ◼ ETA Editor's Note A successful appeal does not warrant ADA compliance....
Search Results "Compliance"
-
1.9.1.5 Special conditions for persons with disabilities requiring appeals action ratification
-
Gaps: ADA Standard Section 1002.4.3
EXCEPTION: Where compliance is not operationally or structurally feasible, ramps, bridge plates, or similar devices complying with the applicable requirements of 36 CFR 1192.83(c) shall...
-
Dispersion: ADA Standard Section 235.2.1
Section 235.2.1 covers scoping requirements in the current ADA Standards for dispersion of boat slips.
-
[2010 ADA Standards] 105.1 General
Copies of the referenced standards may be inspected at the Architectural and Transportation Barriers Compliance Board, 1331 F Street, NW, Suite 1000, Washington, DC 20004; at the Department...
-
11B-810.2.2 Dimensions
Access Board's Note to Reader: The Department of Transportation's ADA Standards indicate that compliance is required to the extent construction specifications are within a public entity's...
-
11B-404.3.2 Maneuvering clearance
Exception: Where automatic doors and gates remain open in the power-off condition, compliance with Section 11B-404.2.4 shall not be required....
-
11B-705.1.2.2.2.1 One entrance/exit point
Existing parallel curb ramps with detectable warnings in compliance with the code requirements in effect at the time of installation shall not be required to provide a minimum 36 inches...
-
101.4.5 Fire prevention
ETA Editor's Note Sections from the California Building Code Chapter 1 that are not adopted by the Division of the State Architect - Access Compliance (DSA-AC) have been omitted....
-
CHAPTER 35 REFERENCED STANDARDS
ETA Editor's Note Referenced standards that are not adopted by Division of the State Architect - Access Compliance (DSA-AC) have been omitted....
-
11B-404.3.2 Maneuvering clearance
Exception: Where automatic doors and gates remain open in the power-off condition, compliance with Section 11B-404.2.4 shall not be required....
-
11B-705.1.2.2.2.1 One entrance/exit point
Existing parallel curb ramps with detectable warnings in compliance with the code requirements in effect at the time of installation shall not be required to provide a minimum 36 inches...
-
11B-810.2.2 Dimensions
Access Board's Note to Reader: The Department of Transportation's ADA Standards indicate that compliance is required to the extent construction specifications are within a public entity's...
-
[2010 ADA Standards] 105.1 General
Copies of the referenced standards may be inspected at the Architectural and Transportation Barriers Compliance Board, 1331 F Street, NW, Suite 1000, Washington, DC 20004; at the Department...
-
12206(c)(2)(C) Title III
.-- The Attorney General, in coordination with the Secretary of Transportation and the Chair of the Architectural Transportation Barriers Compliance Board, shall implement such plan for...
-
Sec. 469.105(a)
(a) The owner of a building or facility described by Section 469.101 is responsible for having the building or facility inspected for compliance with the standards and specifications adopted...
-
§35.177 Effect of unavailability of technical assistance
A public entity shall not be excused from compliance with the requirements of this part because of any failure to receive technical assistance, including any failure in the development or...
-
2.4.1
2.4.1 Based on the methods for measuring compliance, define what remedial actions are acceptable when construction elements exceed tolerances....
-
ACCESSIBLE ELEMENT
[DSA-AC] An element specified by the regulations adopted by the Division of the State Architect-Access Compliance. Advisory Definition of ACCESSIBLE ELEMENT. ...
-
68.20(a) Public Buildings
(a) A building or facility used by the public is subject to compliance with the Texas Accessibility Standards (hereinafter "TAS") if it is constructed, renovated, or modified, in whole or...
-
ACCESSIBLE ELEMENT
[DSA-AC] An element specified by the regulations adopted by the Division of the State Architect-Access Compliance. Advisory Definition of ACCESSIBLE ELEMENT. ...
-
11B-249.1.2
Newly constructed commercial places of public amusement shall provide no fewer than one adult changing facility in compliance with Section 11B-813....
-
III-7.2100 Equivalent facilitation
If a facility complies with a State or local building code, will it be considered in compliance with the ADA? Possibly....
-
V. Enforcement and Termination
In any dispute regarding compliance with any provision of this Agreement, Harris County will bear the burden of demonstrating that it is in compliance with this Agreement....
- Inpro Corporation IPC® HR9 Northern Hardwoods® Real Wood Handrail