Floor space and location. The minimum floor space provided at a water closet shall be 48 inches (1219 mm) in clear width....
Search Results "Clear Floor Area"
Commonly Searched Documents
- 
    
  
  1134A.7, Item 1
  
 - 
    
  
  4) Where the Standard is silent about changes in level
  
4) Where the Standard is silent about changes in level, such as 604.3 around a water closet or in a toilet compartment: Since there is no mention of the phrase "changes in level...
 - 
    
  
  4.10.10 Floor Surfaces
  
Floor surfaces shall comply with 4.5....
 - 
    
  
  4.10.10 FLOOR SURFACES
  
Floor surfaces shall comply with 4.5....
 - 
    
  
  1133A.7, Item 3
  
A clear floor space shall not extend into the knee and toe space more than 19 inches (483 mm)....
 - 
    
  
  1133A.7, Item 3
  
A clear floor space shall not extend into the knee and toe space more than 19 inches (483 mm)....
 - 
    
  
  1134A.7, Item 1
  
Floor space and location. The minimum floor space provided at a water closet shall be 48 inches (1219 mm) in clear width. ...
 - 
    
  
  407.4.2 Floor Surfaces
  
Floor surfaces in elevator cars shall comply with 302 and 303....
 - 
    
  
  407.4.2 Floor Surfaces
  
Floor surfaces in elevator cars shall comply with 302 and 303....
 - 
    
  
  Section 2. Ground floor
  
"Ground floor" means a floor of a building with a building entrance on an accessible route. A building may have one or more ground floors....
 - 
    
  
  608.2.2.1 Clearance
  
A 30 inch (760 mm) wide minimum by 60 inch (1525 mm) long minimum clearance shall be provided adjacent to the open face of the shower compartment. EXCEPTION: A lavatory complying...
 - 
    
  
  Obstructions
  
Obstructions “Obstructions” are also prohibited by TAS 604.3.2 within the required water closet clearance. An obstruction is any element that violates the protruding object...
 - 
    
  
  608.2.2.1 Clearance
  
A 30 inch (760 mm) wide minimum by 60 inch (1525 mm) long minimum clearance shall be provided adjacent to the open face of the shower compartment. EXCEPTION: A lavatory complying...
 - 
    
  
  608.2.2.1 Clearance
  
608.2.2.1 Clearance. A 30 inch (760 mm) wide minimum by 60 inch (1525 mm) long minimum clearance shall be provided adjacent to the open face of the shower compartment. EXCEPTION:...
 - 
    
  
  6.14.1 Clear Width
  
Gate openings and openings in barriers for pedestrian passage shall provide a clear width of 36 inches (915 mm), complying with ODAAG, section 1017.3 Clear Tread Width....
 - 
    
  
  11B-203.10 Raised refereeing, judging and scoring areas
  
11B-203.10 Raised refereeing, judging and scoring areas....
 - 
    
  
  11B-803.3 Door swing
  
Doors shall not swing into the room unless a turning space complying with Section 11B-305.3 is provided beyond the arc of the door swing.
 - 
    
  
  11B-803.3 Door swing
  
Doors shall not swing into the room unless a turning space complying with Section 11B-305.3 is provided beyond the arc of the door swing.
 - 
    
  
  11B-803.3 Door swing
  
Doors shall not swing into the room unless a turning space complying with Section 11B-304.3 is provided beyond the arc of the door swing.
 - 
    
  
  Assembly Areas [4.33]
  
Assembly Areas [4.33] ADAAG requirements for assembly areas apply to areas where groups of people gather for recreational, educational, political, social, or amusement purposes or for...
 - 
    
  
  1009.3 Stairways
  
In order to be considered part of an accessible means of egress, a stairway between stories shall comply with Sections 1009.3.1 through 1009.3.3. [DSA·AC & HCD 1-AC] In addition,...
 - 
    
  
  1009.7.4 Stairways
  
Stairways that are part of the means of egress for the exterior area for assisted rescue shall provide a clear width of 48 inches (1220 mm) between handrails....
 - 
    
  
  1007.7.6 Stairway
  
Stairways that are part of the means of egress for the exterior area for assisted rescue shall provide a clear width of 48 inches (1219 mm) between handrails....
 - 
    
  
  1009.7.4 Stairways
  
Stairways that are part of the means of egress for the exterior area for assisted rescue shall provide a minimum clear width of 48 inches (1220 mm) between handrails....